User name Adaq
Log entry time 17:51:17 on February12,2000
Entry number 33749
keyword=Kin4: MCEEP vs. data
Kinematics 4 for 89044: comparison between MCEEP and data for two-body breakup of 3He. MCEEP used the Salme spectral function, with 0.84 spectroscopic factor and open collimator with spectrometer apertures ala LeRose. Internal brems. and eloss effects were included. A gaussian resolution was added to the beam energy to roughly mock up observed resolution. The missing mass cut extended to 10 MeV in the MCEEP calculation. The total counts within this missing mass cut were determined. In addition, the total counts within this cut and the q,omega,pmiss,zvertex cuts were determined. Further, the data was corrected for a 4% deadtime. The results:
Data MCEEP Data/MCEEP
--- ----- ---------
Em cuts 85K 96K 0.88
All cuts 2.1K 2.9K 0.73