Log entry time 11:17:56 on February18,2000
Entry number 34410
keyword=access for Q2 electron fault
Folts and his team made access to reset Q3 which read Quenched,
overtemperature fault. During ramp up of Q3, they decided
to ramp both Q3 and Q2 down and look at filters, because
the overtemperature seems real. They have put fans on the
power supplies of both, and we're ramping up at this moment.