• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name F.Benmokhtar

    Log entry time 00:13:46 on March 5,2000

    Entry number 35506

    keyword=Shift Summary

    Shift crew: F. Benmokhtar, Bitao Hu, Chai Zhengwei, Dave Meekins.

    Kin#73:
    -----
    Spectrometer setting: thetae = 24.5, Pe = 630.9 MeV/c.
    Run# 2564 Carbon pointing, raster off.
    Run# 2565 He3 test run, raster on.
    Run# 2566 He3, I = 2 microA.

    Kin#74/75:
    -------
    Spectrometer Setting: thetae = 27.0, Pe = 628.3 MeV/c.
    Run# 2567 He3, I = 2 microA, raster on.

    Kin#76:
    -----
    Sperctrometer Setting: thetae = 30.8, Pe = 623.8 MeV/c.
    Run# 2568, He3, I = 2 microA test run (not enough statistic).
    Run# 2569, He3, I = 5 microA, raster on.
    Run# 2570, Carbon pointing, I = 30 microA, raster off.

    Kin#78:
    -----
    Spectrometer Setting: thetae = 35.0, Pe = 618.4 MeV/c.
    Run# 2571, He3, test run.
    Run# 2572, He3, I = 5 microA, raster on.

    Kin#80:
    -----
    Spectrometer Setting: thetae = 39.2, Pe = 612.4 MeV/c.
    Run# 2573, He3, I = 8 microA, raster on.

    Kin#81:
    -----
    Spectrometer Setting: thetae = 41.24, Pe = 609.6 MeV/c.
    Run# 2574, He3, I = 10-15 microA, raster on.
    Run# 2575, He3, I = 15 microA, raster on.
    Run# 2576, Carbon, I = 40 microA, raster on.
    Run# 2577, Carbon pointing, I = 40 microA, raster off.

    ###################################################

    Energy change to 1.254 GeV:
    -------------------
    8:20... Start energy change. MCC said that it will take about 2 hours.

    Kin#90
    -----
    9:15...Change the Hadron Momentum to 1.4730 GeV/c.
    ..........Cycling Hadron Magnet: Q2 and Q3 setting to 1400 Amps.
    ..........Change Electron Momentum to 1.2347 GeV/c.
    ..........Cycling Electron Magnet: Q2 and Q3 setting to 1600 Amps.
    9:30...Move Electron Spectrometer to 15.2 deg. (it takes 20 min).
    10:30 MCC called and said that we can't run with OTR in for currents higher than
    50 microA during the night because the accelerator trips too much radiation.
    10:45..Asking for 4 microA, raster off to do the HARP measurement.
    11:00..HARP Scan, I = 4 microA. Run#588. Raster off.
    11:10..Raster size checked with carbon target.
    11:20..HARP scan, I = 4 mocroA. Run#589. Raster on with carbon target size not ...........good.
    11:50..HARP scan again (raster size not good), Run#590.
    12:00..HARP scan again. Run#591, 592, 593..(raster size not good).
    12:05.. goes to the next shift.