Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 11:27:45 on September 27, 2000
Entry number 48412
keyword=Start_Run_1027_Tar=absence,Type=Pulser,Pmom=1.188,Emom=3.954,Ene=4527,Angle_e=14.077,Angle_h=54.201
Beginning-of-run EPICS data for Run Number 1027 at Wed Sep 27 11:27:14 EDT 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1,ps2=1000,ps3=1,ps4=9999,ps5=1,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 526.26
Right Arm Q1 momentum : 0.699874
Right Arm Q1 gauss meter : -0.01319
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 301.278
Right Arm Q2 momentum : 0.700048
Right Arm Q2 gauss meter : 0.15719
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 240.97
Right Arm D1 momentum : 0.467668
Right Arm D1 NMR : 0.173546
Right Arm Q3 power supply current : 278.341
Right Arm Q3 momentum : 0.700428
Right Arm Q3 gauss meter : 0.12408
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 526.61
Left Arm Q1 momentum : 0.699971
Left Arm Q1 gauss meter : -0.04453
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 301.498
Left Arm Q2 momentum : 0.700181
Left Arm Q2 gauss meter : 0.15899
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 233.634
Left Arm D1 momentum : 0.70001
Left Arm D1 NMR : 0.25924
Left Arm Q3 power supply current : 278.637
Left Arm Q3 momentum : 0.699884
Left Arm Q3 gauss meter : -0.13815
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 0
Current on Unser monitor : 1.83257
Current on Upstream bcm : 0
Current on Downstream bcm : 0
Upstream Cavity Coefficient : 0
Downstream Cavity Coefficient : 0
Current on IBC0L02 (source) : 4.30451
Beam energy : 5030.83
MBSY1c magnet current (amp) : 1.33514e-05
Radiator 5V Linear Supply :
Radiator Encoder :
haBDSPOS : 6.517e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.9
haSC200_6_Sensor_2_R : 7.45
haSC200_6_Sensor_3_R : 33.72
haSC200_6_Sensor_4_R : 36.02
haHe_Omega_DPG_Sensor_R : -0.041
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 0
haITC502_4_Sensor_2_R : 0
haITC502_4_Sensor_3_R : 0
haITC502_5_Sensor_1_R : 94.98
haITC502_5_Sensor_2_R : 94.98
haITC502_5_Sensor_3_R : 291.7
haITC502_6_Sensor_1_R : 94.98
haITC502_6_Sensor_2_R : 94.98
haITC502_6_Sensor_3_R : 30.49
Right Arm Arm Collimator : 0.364063
Left Arm Arm Collimator : 0.366016
HacR_HPM_LVDT:VALr : -1386
HacR_VPM_LVDT:VALr : -2304
HacR_HPE1313A:0_Ch58 : -0.549805
HacR_HPE1313A:0_Ch55 : 22.0215
HacR_HPE1313A:0_Ch54 : -0.825195
HacR_alignROLL : -0.343788
HacR_alignPITCH : -0.00624123
HacR_alignHPT : -1.23509
HacL_HPM_LVDT:VALr : -7807
HacL_VPM_LVDT:VALr : 991
HacL_HPE1313A:0_Ch58 : -0.165527
HacL_HPE1313A:0_Ch55 : 23.2422
HacL_HPE1313A:0_Ch54 : -0.0283203
HacL_alignROLL : 0.315065
HacL_alignPITCH : -0.117334
HacL_alignHPT : 4.8423
FPP Chamber 1 Threshold :
FPP Chamber 2 Threshold :
FPP Chamber 3 Threshold :
FPP Chamber 4 Threshold :
FPP Chamber 1 Output gasflow :
FPP Chamber 2 Output gasflow :
FPP Chamber 3 Output gasflow :
FPP Chamber 4 Output gasflow :
For Fpp carbon door IN Limit= 0 means door is IN
For Fpp carbon door IN Limit= 1 means door is OUT
FPP 1.5 inch door left IN limit :
FPP 3.0 inch door left IN limit :
FPP 6.0 inch door left IN limit :
FPP 9.0 inch door left IN limit :
FPP 1.5 inch door right IN limit :
FPP 3.0 inch door right IN limit :
FPP 6.0 inch door right IN limit :
FPP 9.0 inch door right IN limit :
Right Arm Angle Floor Angle : 16
Right Arm Angle Vernier : -34.2
Right Arm Scattering Angle : 16.0082
Left Arm Angle Floor Angle : 16
Left Arm Angle Vernier : 31.1
Left Arm Scattering Angle : 15.9675
Wien angle :
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 80
Laser power Hall A : 55
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88