User name adev
Log entry time 12:36:33 on September 27, 2000
Entry number 48414
keyword=Start_Run_1028_Tar=absence,Type=Pulser,Pmom=1.188,Emom=3.954,Ene=4527,Angle_e=14.077,Angle_h=54.201
Beginning-of-run EPICS data for Run Number 1028 at Wed Sep 27 12:36:04 EDT 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1,ps2=1000,ps3=1,ps4=9999,ps5=1,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 526.295
Right Arm Q1 momentum : 0.699921
Right Arm Q1 gauss meter : -0.013199
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 301.182
Right Arm Q2 momentum : 0.699826
Right Arm Q2 gauss meter : 0.15715
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 240.925
Right Arm D1 momentum : 0.699997
Right Arm D1 NMR : 0.25976
Right Arm Q3 power supply current : 278.489
Right Arm Q3 momentum : 0.699881
Right Arm Q3 gauss meter : 0.12405
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 526.61
Left Arm Q1 momentum : 0.699971
Left Arm Q1 gauss meter : -0.04452
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 301.635
Left Arm Q2 momentum : 0.700499
Left Arm Q2 gauss meter : 0.15891
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 233.63
Left Arm D1 momentum : 0.700011
Left Arm D1 NMR : 0.25924
Left Arm Q3 power supply current : 278.67
Left Arm Q3 momentum : 0.699968
Left Arm Q3 gauss meter : -0.13815
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 0
Current on Unser monitor : 0.867645
Current on Upstream bcm : 0
Current on Downstream bcm : 0
Upstream Cavity Coefficient : 0
Downstream Cavity Coefficient : 0
Current on IBC0L02 (source) : 4.39819
Beam energy : 5030.83
MBSY1c magnet current (amp) : 1.33514e-05
Radiator 5V Linear Supply :
Radiator Encoder :
haBDSPOS : 6.517e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.96
haSC200_6_Sensor_2_R : 7.43
haSC200_6_Sensor_3_R : 33.77
haSC200_6_Sensor_4_R : 36.04
haHe_Omega_DPG_Sensor_R : -0.042
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 0
haITC502_4_Sensor_2_R : 0
haITC502_4_Sensor_3_R : 0
haITC502_5_Sensor_1_R : 94.98
haITC502_5_Sensor_2_R : 94.98
haITC502_5_Sensor_3_R : 291.7
haITC502_6_Sensor_1_R : 94.98
haITC502_6_Sensor_2_R : 94.98
haITC502_6_Sensor_3_R : 30.49
Right Arm Arm Collimator : 0.364063
Left Arm Arm Collimator : 0.366016
HacR_HPM_LVDT:VALr : -1363
HacR_VPM_LVDT:VALr : -2313
HacR_HPE1313A:0_Ch58 : -0.548828
HacR_HPE1313A:0_Ch55 : 22.0215
HacR_HPE1313A:0_Ch54 : -0.818359
HacR_alignROLL : -0.339295
HacR_alignPITCH : -0.00720489
HacR_alignHPT : -1.26228
HacL_HPM_LVDT:VALr : -7796
HacL_VPM_LVDT:VALr : 971
HacL_HPE1313A:0_Ch58 : -0.164062
HacL_HPE1313A:0_Ch55 : 23.3398
HacL_HPE1313A:0_Ch54 : -0.0288086
HacL_alignROLL : 0.32157
HacL_alignPITCH : -0.118644
HacL_alignHPT : 4.82577
FPP Chamber 1 Threshold :
FPP Chamber 2 Threshold :
FPP Chamber 3 Threshold :
FPP Chamber 4 Threshold :
FPP Chamber 1 Output gasflow :
FPP Chamber 2 Output gasflow :
FPP Chamber 3 Output gasflow :
FPP Chamber 4 Output gasflow :
For Fpp carbon door IN Limit= 0 means door is IN
For Fpp carbon door IN Limit= 1 means door is OUT
FPP 1.5 inch door left IN limit :
FPP 3.0 inch door left IN limit :
FPP 6.0 inch door left IN limit :
FPP 9.0 inch door left IN limit :
FPP 1.5 inch door right IN limit :
FPP 3.0 inch door right IN limit :
FPP 6.0 inch door right IN limit :
FPP 9.0 inch door right IN limit :
Right Arm Angle Floor Angle : 16
Right Arm Angle Vernier : -34.2
Right Arm Scattering Angle : 16.0084
Left Arm Angle Floor Angle : 16
Left Arm Angle Vernier : 31.1
Left Arm Scattering Angle : 15.9676
Wien angle :
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 80
Laser power Hall A : 55
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88