Main INDEX
Monthly INDEX
PREV
NEXT
User name templon
Log entry time 17:55:08 on September28,2000
Entry number 48446
keyword=cabling changes
1) aerogel cerenkov cabled up in right spectrometer (elektron det pkg but hadron
..... spect for e97111. aerogel right cabled to adc in slot 23, patch cable 1 goes
..... channel 48 of ADC, patch cable 16 goes to channel 63.
..... aerogel left cabled to adc in slot 24, signal (patch cable) 1 to chan 48,
..... signal 16 cabled to chan 64.
.
2) deadtime pulser in same arm found dangling. reconnected to tdc in slot
..... 19, channel 84
.
3) L arm, plane 4 VDC, cable 12 found shifted to left at TDC input. replugged.
.
4) L arm still has noisy VDC. Bogdan and Mark J checking.
.
5) Brad Sawatzky has already made initial changes to detmap.config to
..... make espace grok physical package swap plus our detpkg function swap