User name adev
Log entry time 10:58:14 on September 29, 2000
Entry number 48455
keyword=Start_Run_1049_Tar=absence,Type=Pulser,Pmom=1.188,Emom=3.954,Ene=4527,Angle_e=14.077,Angle_h=54.201
Beginning-of-run EPICS data for Run Number 1049 at Fri Sep 29 10:57:52 EDT 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1,ps2=1000,ps3=1,ps4=9999,ps5=1,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 526.365
Right Arm Q1 momentum : 0.700014
Right Arm Q1 gauss meter : -0.0132
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 301.266
Right Arm Q2 momentum : 0.700022
Right Arm Q2 gauss meter : 0.15718
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 241.009
Right Arm D1 momentum : 0.7
Right Arm D1 NMR : 0.259762
Right Arm Q3 power supply current : 278.553
Right Arm Q3 momentum : 0.700043
Right Arm Q3 gauss meter : 0.12408
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 526.295
Left Arm Q1 momentum : 0.699552
Left Arm Q1 gauss meter : -0.04453
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 301.291
Left Arm Q2 momentum : 0.6997
Left Arm Q2 gauss meter : 0.1588
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current :
Left Arm D1 momentum : 0.700002
Left Arm D1 NMR : 0.259237
Left Arm Q3 power supply current : 278.69
Left Arm Q3 momentum : 0.700019
Left Arm Q3 gauss meter : -0.1381
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 0.0228986
Current on Unser monitor : 1.77055
Current on Upstream bcm : 0.0251788
Current on Downstream bcm : 0.0206016
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 0.00142881
Beam energy : 825.959
MBSY1c magnet current (amp) : 0.0377197
Radiator 5V Linear Supply :
Radiator Encoder :
haBDSPOS : -44989
haL1_Fan_frequency_R : 64
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 243.37
haSC200_6_Sensor_2_R : 227.22
haSC200_6_Sensor_3_R : 0
haSC200_6_Sensor_4_R : 35.82
haHe_Omega_DPG_Sensor_R : 6.176
haITC502_1_Sensor_1_R : 5.67
haITC502_1_Sensor_2_R : 5.66
haITC502_1_Sensor_3_R : 5.74999
haITC502_4_Sensor_1_R : 5.9
haITC502_4_Sensor_2_R : 164.2
haITC502_4_Sensor_3_R : 81.7
haITC502_5_Sensor_1_R : 5.69
haITC502_5_Sensor_2_R : 5.69
haITC502_5_Sensor_3_R : 207.2
haITC502_6_Sensor_1_R : 5.69
haITC502_6_Sensor_2_R : 5.68
haITC502_6_Sensor_3_R : 27.5
Right Arm Arm Collimator : 0.364063
Left Arm Arm Collimator : 0.366064
HacR_HPM_LVDT:VALr : -1262
HacR_VPM_LVDT:VALr : -1620
HacR_HPE1313A:0_Ch58 : -0.543457
HacR_HPE1313A:0_Ch55 : 22.6074
HacR_HPE1313A:0_Ch54 : -0.792969
HacR_alignROLL : -0.312471
HacR_alignPITCH : -0.0124882
HacR_alignHPT : -1.39063
HacL_HPM_LVDT:VALr : -8707
HacL_VPM_LVDT:VALr : 1914
HacL_HPE1313A:0_Ch58 : -0.163086
HacL_HPE1313A:0_Ch55 : 23.6816
HacL_HPE1313A:0_Ch54 : -0.0327148
HacL_alignROLL : 0.310562
HacL_alignPITCH : -0.119674
HacL_alignHPT : 5.84785
Right Arm Angle Floor Angle : 16
Right Arm Angle Vernier : -34.2
Right Arm Scattering Angle : 16.0093
Left Arm Angle Floor Angle : 16
Left Arm Angle Vernier : 31.5
Left Arm Scattering Angle : 15.9629
Wien angle :
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 340
Laser power Hall A : 63
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88