User name adev
Log entry time 15:54:53 on September 29, 2000
Entry number 48487
keyword=Start_Run_1063_Tar=absence,Type=Pulser,Pmom=1.188,Emom=3.954,Ene=4527,Angle_e=14.077,Angle_h=54.201
Beginning-of-run EPICS data for Run Number 1063 at Fri Sep 29 15:54:30 EDT 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1000,ps2=1000,ps3=1000,ps4=9999,ps5=1,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 526.295
Right Arm Q1 momentum : 0.699921
Right Arm Q1 gauss meter : -0.013195
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 301.206
Right Arm Q2 momentum : 0.699881
Right Arm Q2 gauss meter : 0.15721
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 240.981
Right Arm D1 momentum : 0.7
Right Arm D1 NMR : 0.259762
Right Arm Q3 power supply current : 278.386
Right Arm Q3 momentum : 0.699623
Right Arm Q3 gauss meter : 0.12407
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 526.19
Left Arm Q1 momentum : 0.699412
Left Arm Q1 gauss meter : -0.04451
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 301.484
Left Arm Q2 momentum : 0.700149
Left Arm Q2 gauss meter : 0.15887
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 233.671
Left Arm D1 momentum : 0.70001
Left Arm D1 NMR : 0.25924
Left Arm Q3 power supply current : 278.705
Left Arm Q3 momentum : 0.700055
Left Arm Q3 gauss meter : -0.13809
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 0.0225422
Current on Unser monitor : 1.27679
Current on Upstream bcm : 0.0244438
Current on Downstream bcm : 0.020381
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 0.00142881
Beam energy : 825.959
MBSY1c magnet current (amp) : 0.0377197
Radiator 5V Linear Supply :
Radiator Encoder :
haBDSPOS : -44989
haL1_Fan_frequency_R : 65
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 243.57
haSC200_6_Sensor_2_R : 225.36
haSC200_6_Sensor_3_R : 0.03
haSC200_6_Sensor_4_R : 35.82
haHe_Omega_DPG_Sensor_R : 5.687
haITC502_1_Sensor_1_R : 5.79
haITC502_1_Sensor_2_R : 5.78
haITC502_1_Sensor_3_R : 5.85999
haITC502_4_Sensor_1_R : 6
haITC502_4_Sensor_2_R : 134
haITC502_4_Sensor_3_R : 83.1
haITC502_5_Sensor_1_R : 5.81
haITC502_5_Sensor_2_R : 5.8
haITC502_5_Sensor_3_R : 201.9
haITC502_6_Sensor_1_R : 5.81
haITC502_6_Sensor_2_R : 5.8
haITC502_6_Sensor_3_R : 27.32
Right Arm Arm Collimator : 0.364063
Left Arm Arm Collimator : 0.366064
HacR_HPM_LVDT:VALr : -1266
HacR_VPM_LVDT:VALr : -1651
HacR_HPE1313A:0_Ch58 : -0.542969
HacR_HPE1313A:0_Ch55 : 22.6562
HacR_HPE1313A:0_Ch54 : -0.791992
HacR_alignROLL : -0.310934
HacR_alignPITCH : -0.0130034
HacR_alignHPT : -1.38814
HacL_HPM_LVDT:VALr : -8466
HacL_VPM_LVDT:VALr : 1504
HacL_HPE1313A:0_Ch58 : -0.164062
HacL_HPE1313A:0_Ch55 : 23.8281
HacL_HPE1313A:0_Ch54 : -0.0341797
HacL_alignROLL : 0.310325
HacL_alignPITCH : -0.11946
HacL_alignHPT : 5.57757
Right Arm Angle Floor Angle : 16
Right Arm Angle Vernier : -34.2
Right Arm Scattering Angle : 16.0093
Left Arm Angle Floor Angle : 16
Left Arm Angle Vernier : 31.5
Left Arm Scattering Angle : 15.9648
Wien angle :
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 90
Laser power Hall A : 63
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88