User name adev
Log entry time 17:24:47 on September 29, 2000
Entry number 48507
keyword=Start_Run_1074_Tar=absence,Type=Pulser,Pmom=1.188,Emom=3.954,Ene=4527,Angle_e=14.077,Angle_h=54.201
Beginning-of-run EPICS data for Run Number 1074 at Fri Sep 29 17:24:33 EDT 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1000,ps2=1000,ps3=1000,ps4=9999,ps5=1,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 526.365
Right Arm Q1 momentum : 0.700014
Right Arm Q1 gauss meter : -0.013191
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 301.216
Right Arm Q2 momentum : 0.699905
Right Arm Q2 gauss meter : 0.15715
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 240.982
Right Arm D1 momentum : 0.700001
Right Arm D1 NMR : 0.259762
Right Arm Q3 power supply current : 278.401
Right Arm Q3 momentum : 0.69966
Right Arm Q3 gauss meter : 0.1241
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 526.365
Left Arm Q1 momentum : 0.699645
Left Arm Q1 gauss meter : -0.04448
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 301.457
Left Arm Q2 momentum : 0.700087
Left Arm Q2 gauss meter : 0.15892
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 233.668
Left Arm D1 momentum : 0.700008
Left Arm D1 NMR : 0.259239
Left Arm Q3 power supply current : 278.704
Left Arm Q3 momentum : 0.700053
Left Arm Q3 gauss meter : -0.13809
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 0.022681
Current on Unser monitor : 0.284627
Current on Upstream bcm : 0.0242103
Current on Downstream bcm : 0.0211518
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 0.00142881
Beam energy : 825.959
MBSY1c magnet current (amp) : 0.0377197
Radiator 5V Linear Supply :
Radiator Encoder :
haBDSPOS : -44989
haL1_Fan_frequency_R : 66
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 243.78
haSC200_6_Sensor_2_R : 223.42
haSC200_6_Sensor_3_R : 0.15
haSC200_6_Sensor_4_R : 35.85
haHe_Omega_DPG_Sensor_R : 5.662
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.78
haITC502_1_Sensor_3_R : 5.86999
haITC502_4_Sensor_1_R : 6
haITC502_4_Sensor_2_R : 139.4
haITC502_4_Sensor_3_R : 88
haITC502_5_Sensor_1_R : 5.82
haITC502_5_Sensor_2_R : 5.81
haITC502_5_Sensor_3_R : 202.8
haITC502_6_Sensor_1_R : 5.81
haITC502_6_Sensor_2_R : 5.81
haITC502_6_Sensor_3_R : 27.43
Right Arm Arm Collimator : 0.364014
Left Arm Arm Collimator : 0.366064
HacR_HPM_LVDT:VALr : -1266
HacR_VPM_LVDT:VALr : -1628
HacR_HPE1313A:0_Ch58 : -0.54248
HacR_HPE1313A:0_Ch55 : 22.8027
HacR_HPE1313A:0_Ch54 : -0.789551
HacR_alignROLL : -0.308293
HacR_alignPITCH : -0.0136513
HacR_alignHPT : -1.38853
HacL_HPM_LVDT:VALr : -8478
HacL_VPM_LVDT:VALr : 1505
HacL_HPE1313A:0_Ch58 : -0.163086
HacL_HPE1313A:0_Ch55 : 23.8281
HacL_HPE1313A:0_Ch54 : -0.0332031
HacL_alignROLL : 0.30986
HacL_alignPITCH : -0.11946
HacL_alignHPT : 5.59008
Right Arm Angle Floor Angle : 16
Right Arm Angle Vernier : -34.2
Right Arm Scattering Angle : 16.0093
Left Arm Angle Floor Angle : 16
Left Arm Angle Vernier : 31.5
Left Arm Scattering Angle : 15.9647
Wien angle :
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 90
Laser power Hall A : 63
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88