User name adev
Log entry time 18:44:58 on September 29, 2000
Entry number 48522
keyword=Start_Run_1080_Tar=absence,Type=Pulser,Pmom=1.188,Emom=3.954,Ene=4527,Angle_e=14.077,Angle_h=54.201
Beginning-of-run EPICS data for Run Number 1080 at Fri Sep 29 18:44:39 EDT 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1,ps2=1000,ps3=1,ps4=9999,ps5=1,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 642.845
Right Arm Q1 momentum : 0.854921
Right Arm Q1 gauss meter : -0.016118
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 368.085
Right Arm Q2 momentum : 0.855281
Right Arm Q2 gauss meter : 0.19358
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 293.895
Right Arm D1 momentum : 0.854999
Right Arm D1 NMR : 0.31728
Right Arm Q3 power supply current : 339.927
Right Arm Q3 momentum : 0.854284
Right Arm Q3 gauss meter : 0.15253
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 643.055
Left Arm Q1 momentum : 0.854749
Left Arm Q1 gauss meter : -0.05441
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 368.4
Left Arm Q2 momentum : 0.855551
Left Arm Q2 gauss meter : 0.19481
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 285.647
Left Arm D1 momentum : 0.855002
Left Arm D1 NMR : 0.316584
Left Arm Q3 power supply current : 340.427
Left Arm Q3 momentum : 0.85509
Left Arm Q3 gauss meter : -0.16962
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 0.0229883
Current on Unser monitor : 0.624592
Current on Upstream bcm : 0.0250156
Current on Downstream bcm : 0.0209609
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 0.00142881
Beam energy : 825.959
MBSY1c magnet current (amp) : 0.0377197
Radiator 5V Linear Supply :
Radiator Encoder :
haBDSPOS : -44989
haL1_Fan_frequency_R : 65.5
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.53
haSC200_6_Sensor_2_R : 222.99
haSC200_6_Sensor_3_R : -0.42
haSC200_6_Sensor_4_R : 35.55
haHe_Omega_DPG_Sensor_R : 5.643
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.79
haITC502_1_Sensor_3_R : 5.86999
haITC502_4_Sensor_1_R : 6
haITC502_4_Sensor_2_R : 137.9
haITC502_4_Sensor_3_R : 81.3
haITC502_5_Sensor_1_R : 5.81
haITC502_5_Sensor_2_R : 5.81
haITC502_5_Sensor_3_R : 205.3
haITC502_6_Sensor_1_R : 5.82
haITC502_6_Sensor_2_R : 5.8
haITC502_6_Sensor_3_R : 27.43
Right Arm Arm Collimator : 0.61499
Left Arm Arm Collimator : 0.616992
HacR_HPM_LVDT:VALr : -1214
HacR_VPM_LVDT:VALr : -1591
HacR_HPE1313A:0_Ch58 : -0.543945
HacR_HPE1313A:0_Ch55 : 22.4609
HacR_HPE1313A:0_Ch54 : -0.792969
HacR_alignROLL : -0.312155
HacR_alignPITCH : -0.0113915
HacR_alignHPT : -1.44118
HacL_HPM_LVDT:VALr : -8452
HacL_VPM_LVDT:VALr : 1558
HacL_HPE1313A:0_Ch58 : -0.166504
HacL_HPE1313A:0_Ch55 : 23.3887
HacL_HPE1313A:0_Ch54 : -0.0327148
HacL_alignROLL : 0.310105
HacL_alignPITCH : -0.116172
HacL_alignHPT : 5.56203
Right Arm Angle Floor Angle : 16
Right Arm Angle Vernier : -34.2
Right Arm Scattering Angle : 16.0096
Left Arm Angle Floor Angle : 16
Left Arm Angle Vernier : 31.5
Left Arm Scattering Angle : 15.9649
Wien angle :
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 80
Laser power Hall A : 63
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88