Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 19:36:21 on September 29, 2000
Entry number 48532
keyword=Start_Run_1085_Tar=absence,Type=Pulser,Pmom=1.188,Emom=3.954,Ene=4527,Angle_e=14.077,Angle_h=54.201
Beginning-of-run EPICS data for Run Number 1085 at Fri Sep 29 19:36:04 EDT 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1,ps2=1000,ps3=1,ps4=9999,ps5=1,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 642.88
Right Arm Q1 momentum : 0.854968
Right Arm Q1 gauss meter : -0.016118
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 367.838
Right Arm Q2 momentum : 0.854708
Right Arm Q2 gauss meter : 0.19352
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current :
Right Arm D1 momentum : 0.855
Right Arm D1 NMR : 0.31728
Right Arm Q3 power supply current : 340.372
Right Arm Q3 momentum : 0.855403
Right Arm Q3 gauss meter : 0.15256
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 642.985
Left Arm Q1 momentum : 0.854656
Left Arm Q1 gauss meter : -0.05442
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 368.202
Left Arm Q2 momentum : 0.85509
Left Arm Q2 gauss meter : 0.19471
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 285.639
Left Arm D1 momentum : 0.85501
Left Arm D1 NMR : 0.316587
Left Arm Q3 power supply current : 340.411
Left Arm Q3 momentum : 0.855048
Left Arm Q3 gauss meter : -0.16962
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 97.9194
Current on Unser monitor : 100.238
Current on Upstream bcm : 99.0073
Current on Downstream bcm : 96.5667
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 98.5914
Beam energy : 825.959
MBSY1c magnet current (amp) : 34.0388
Radiator 5V Linear Supply :
Radiator Encoder :
haBDSPOS : -44989
haL1_Fan_frequency_R : 66
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 243
haSC200_6_Sensor_2_R : 223.45
haSC200_6_Sensor_3_R : -0.08
haSC200_6_Sensor_4_R : 35.69
haHe_Omega_DPG_Sensor_R : 5.662
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.79
haITC502_1_Sensor_3_R : 5.86999
haITC502_4_Sensor_1_R : 6
haITC502_4_Sensor_2_R : 134.1
haITC502_4_Sensor_3_R : 80.1
haITC502_5_Sensor_1_R : 5.81
haITC502_5_Sensor_2_R : 5.81
haITC502_5_Sensor_3_R : 205.6
haITC502_6_Sensor_1_R : 5.82
haITC502_6_Sensor_2_R : 5.8
haITC502_6_Sensor_3_R : 27.44
Right Arm Arm Collimator : 0.61499
Left Arm Arm Collimator : 0.616943
HacR_HPM_LVDT:VALr : -1244
HacR_VPM_LVDT:VALr : -1550
HacR_HPE1313A:0_Ch58 : -0.54541
HacR_HPE1313A:0_Ch55 : 22.5098
HacR_HPE1313A:0_Ch54 : -0.796387
HacR_alignROLL : -0.315546
HacR_alignPITCH : -0.0105601
HacR_alignHPT : -1.40902
HacL_HPM_LVDT:VALr : -8459
HacL_VPM_LVDT:VALr : 1560
HacL_HPE1313A:0_Ch58 : -0.168457
HacL_HPE1313A:0_Ch55 : 23.6328
HacL_HPE1313A:0_Ch54 : -0.0351562
HacL_alignROLL : 0.308086
HacL_alignPITCH : -0.115159
HacL_alignHPT : 5.57305
Right Arm Angle Floor Angle : 16
Right Arm Angle Vernier : -34.2
Right Arm Scattering Angle : 16.0094
Left Arm Angle Floor Angle : 16
Left Arm Angle Vernier : 31.5
Left Arm Scattering Angle : 15.9648
Wien angle :
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 395
Laser power Hall A : 63
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88