User name adev
Log entry time 21:05:17 on September 29, 2000
Entry number 48551
keyword=End_of_Run_1091
End-of-run EPICS data for Run Number 1091 at Fri Sep 29 21:05:03 EDT 2000
Right Arm D1 momentum : 0.854999
Right Arm arm angle : 16.0093
Left Arm D1 momentum : 0.855011
Left Arm arm angle : 15.9649
Tiefenbach Hall A energy : 825.103
Right Arm arm mispointing (HPT) : -1.39499
Left Arm arm mispointing (HPT) : 5.5605
Right Arm Q1 power supply current : 642.88
Right Arm Q1 momentum : 0.854968
Right Arm Q1 gauss meter : -0.016108
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 367.784
Right Arm Q2 momentum : 0.854582
Right Arm Q2 gauss meter : 0.19355
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 293.888
Right Arm D1 momentum : 0.854999
Right Arm D1 NMR : 0.31728
Right Arm Q3 power supply current : 340.316
Right Arm Q3 momentum : 0.855262
Right Arm Q3 gauss meter : 0.15261
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 642.985
Left Arm Q1 momentum : 0.854656
Left Arm Q1 gauss meter : -0.05439
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 368.463
Left Arm Q2 momentum : 0.855698
Left Arm Q2 gauss meter : 0.19482
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 285.641
Left Arm D1 momentum : 0.85501
Left Arm D1 NMR : 0.316587
Left Arm Q3 power supply current : 340.428
Left Arm Q3 momentum : 0.855093
Left Arm Q3 gauss meter : -0.16964
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 9.95743
Current on Unser monitor : 10.6192
Current on Upstream bcm : 10.0763
Current on Downstream bcm : 9.83857
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 10.071
MBSY1c Hall A Beam energy : 825.959
MBSY1c magnet current (amp) : 34.0388
MBSY1c Bdl : 206119
MBSY3c Hall C Beam energy : 2392.25
Tiefenbach Hall A energy : 825.103
Tiefenbach Hall C energy : 2383.96
Delta(E)/E width (MV_AI_DXWID) : 4.06566
IPM1C12.XPOS : 1.04299
IPM1H04A.XPOS : -1.39335
IPM1H04A.YPOS : -0.941894
IPM1H04B.XPOS : -0.577447
IPM1H04B.YPOS : -0.931264
Right Arm Arm Collimator : 0.614941
Left Arm Arm Collimator : 0.616943
HacR_HPM_LVDT:VALr : -1257
HacR_VPM_LVDT:VALr : -1467
HacR_HPE1313A:0_Ch58 : -0.54541
HacR_HPE1313A:0_Ch55 : 22.5586
HacR_HPE1313A:0_Ch54 : -0.796875
HacR_alignROLL : -0.315981
HacR_alignPITCH : -0.0106264
HacR_alignHPT : -1.39534
HacL_HPM_LVDT:VALr : -8451
HacL_VPM_LVDT:VALr : 1604
HacL_HPE1313A:0_Ch58 : -0.167969
HacL_HPE1313A:0_Ch55 : 23.6328
HacL_HPE1313A:0_Ch54 : -0.0351562
HacL_alignROLL : 0.309167
HacL_alignPITCH : -0.114871
HacL_alignHPT : 5.55912
haBDSPOS : -44989
haL1_Fan_frequency_R : 67.5
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haH2_P_Fill_Target_R : 25.04
haH2_P_Exhaust_R : 25.36
haH2_P_Fill_Bottle_R : 25.46
haH2_DP_Fill_Exhaust_R : 0
haD2_P_Fill_Target_R : 0
haD2_P_Exhaust_R : 0
haD2_P_Fill_Bottle_R : 0
haD2_DP_Fill_Exhaust_R : 27.438
haSC200_6_Sensor_1_R : 243.01
haSC200_6_Sensor_2_R : 223.55
haSC200_6_Sensor_3_R : 0.02
haSC200_6_Sensor_4_R : 35.7
haHe_Omega_DPG_Sensor_R : 5.66
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.79
haITC502_1_Sensor_3_R : 5.86999
haITC502_2_Sensor_1_R : 94.98
haITC502_2_Sensor_2_R : 94.98
haITC502_2_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 6
haITC502_4_Sensor_2_R : 127.6
haITC502_4_Sensor_3_R : 79.3
haITC502_5_Sensor_1_R : 5.81
haITC502_5_Sensor_2_R : 5.81
haITC502_5_Sensor_3_R : 204.7
haITC502_6_Sensor_1_R : 5.82
haITC502_6_Sensor_2_R : 5.81
haITC502_6_Sensor_3_R : 27.4
Right Arm VDC Top HV :
Right Arm VDC Bottom HV :
Left Arm VDC Top HV :
Left Arm VDC Bottom HV :
Right Arm Arm Collimator : 0.614941
Left Arm Arm Collimator : 0.616992
Wien angle :
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 90
Laser power Hall A : 63