Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 22:07:53 on September 29, 2000
Entry number 48557
keyword=Start_Run_1094_Tar=absence,Type=Pulser,Pmom=1.188,Emom=3.954,Ene=4527,Angle_e=14.077,Angle_h=54.201
Beginning-of-run EPICS data for Run Number 1094 at Fri Sep 29 22:07:37 EDT 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=100,ps2=1000,ps3=100,ps4=9999,ps5=1,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 642.88
Right Arm Q1 momentum : 0.854968
Right Arm Q1 gauss meter : -0.016108
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 368.182
Right Arm Q2 momentum : 0.855506
Right Arm Q2 gauss meter : 0.19365
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 293.887
Right Arm D1 momentum : 0.855
Right Arm D1 NMR : 0.31728
Right Arm Q3 power supply current : 340.259
Right Arm Q3 momentum : 0.85527
Right Arm Q3 gauss meter : 0.15257
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 642.985
Left Arm Q1 momentum : 0.854656
Left Arm Q1 gauss meter : -0.0544
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 368.253
Left Arm Q2 momentum : 0.855208
Left Arm Q2 gauss meter : 0.19483
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 285.649
Left Arm D1 momentum : 0.855005
Left Arm D1 NMR : 0.316585
Left Arm Q3 power supply current : 340.417
Left Arm Q3 momentum : 0.855063
Left Arm Q3 gauss meter : -0.16965
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 5.55413
Current on Unser monitor : 6.28711
Current on Upstream bcm : 5.61976
Current on Downstream bcm : 5.48851
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 5.60627
Beam energy : 825.959
MBSY1c magnet current (amp) : 34.0388
Radiator 5V Linear Supply :
Radiator Encoder :
haBDSPOS : 732012
haL1_Fan_frequency_R : 66.5
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.51
haSC200_6_Sensor_2_R : 223.25
haSC200_6_Sensor_3_R : -0.22
haSC200_6_Sensor_4_R : 35.69
haHe_Omega_DPG_Sensor_R : 5.713
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.78
haITC502_1_Sensor_3_R : 5.86999
haITC502_4_Sensor_1_R : 6
haITC502_4_Sensor_2_R : 123.8
haITC502_4_Sensor_3_R : 79.1
haITC502_5_Sensor_1_R : 5.81
haITC502_5_Sensor_2_R : 5.8
haITC502_5_Sensor_3_R : 204.2
haITC502_6_Sensor_1_R : 5.81
haITC502_6_Sensor_2_R : 5.8
haITC502_6_Sensor_3_R : 27.32
Right Arm Arm Collimator : 0.61499
Left Arm Arm Collimator : 0.616943
HacR_HPM_LVDT:VALr : -1261
HacR_VPM_LVDT:VALr : -1410
HacR_HPE1313A:0_Ch58 : -0.545898
HacR_HPE1313A:0_Ch55 : 22.3145
HacR_HPE1313A:0_Ch54 : -0.797852
HacR_alignROLL : -0.317752
HacR_alignPITCH : -0.00939736
HacR_alignHPT : -1.38762
HacL_HPM_LVDT:VALr : -8434
HacL_VPM_LVDT:VALr : 1647
HacL_HPE1313A:0_Ch58 : -0.169922
HacL_HPE1313A:0_Ch55 : 23.4375
HacL_HPE1313A:0_Ch54 : -0.0341797
HacL_alignROLL : 0.308787
HacL_alignPITCH : -0.113191
HacL_alignHPT : 5.54478
Right Arm Angle Floor Angle : 16
Right Arm Angle Vernier : -34.2
Right Arm Scattering Angle : 16.0093
Left Arm Angle Floor Angle : 16
Left Arm Angle Vernier : 31.5
Left Arm Scattering Angle : 15.965
Wien angle :
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 35
Laser power Hall A : 63
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88