User name adev
Log entry time 22:42:28 on September 29, 2000
Entry number 48561
keyword=Start_Run_1096_Tar=absence,Type=Pulser,Pmom=1.188,Emom=3.954,Ene=4527,Angle_e=14.077,Angle_h=54.201
Beginning-of-run EPICS data for Run Number 1096 at Fri Sep 29 22:42:16 EDT 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=100,ps2=1000,ps3=100,ps4=9999,ps5=1,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 642.88
Right Arm Q1 momentum : 0.854968
Right Arm Q1 gauss meter : -0.016109
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 367.952
Right Arm Q2 momentum : 0.854972
Right Arm Q2 gauss meter : 0.19361
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 293.888
Right Arm D1 momentum : 0.855
Right Arm D1 NMR : 0.31728
Right Arm Q3 power supply current : 340.191
Right Arm Q3 momentum : 0.854946
Right Arm Q3 gauss meter : 0.15256
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 642.95
Left Arm Q1 momentum : 0.85461
Left Arm Q1 gauss meter : -0.05439
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 368.311
Left Arm Q2 momentum : 0.855345
Left Arm Q2 gauss meter : 0.19477
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 285.643
Left Arm D1 momentum : 0.855009
Left Arm D1 NMR : 0.316587
Left Arm Q3 power supply current : 340.366
Left Arm Q3 momentum : 0.854936
Left Arm Q3 gauss meter : -0.16963
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 0.0219612
Current on Unser monitor : 0.619302
Current on Upstream bcm : 0.0241147
Current on Downstream bcm : 0.0199915
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 0.00142881
Beam energy : 825.959
MBSY1c magnet current (amp) : 0.0377197
Radiator 5V Linear Supply :
Radiator Encoder :
haBDSPOS : 732012
haL1_Fan_frequency_R : 66
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.86
haSC200_6_Sensor_2_R : 223.15
haSC200_6_Sensor_3_R : -0.03
haSC200_6_Sensor_4_R : 35.72
haHe_Omega_DPG_Sensor_R : 5.636
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.78
haITC502_1_Sensor_3_R : 5.86999
haITC502_4_Sensor_1_R : 6
haITC502_4_Sensor_2_R : 122
haITC502_4_Sensor_3_R : 78.9
haITC502_5_Sensor_1_R : 5.81
haITC502_5_Sensor_2_R : 5.8
haITC502_5_Sensor_3_R : 204.2
haITC502_6_Sensor_1_R : 5.81
haITC502_6_Sensor_2_R : 5.8
haITC502_6_Sensor_3_R : 27.31
Right Arm Arm Collimator : 0.614941
Left Arm Arm Collimator : 0.616943
HacR_HPM_LVDT:VALr : -1275
HacR_VPM_LVDT:VALr : -1406
HacR_HPE1313A:0_Ch58 : -0.545898
HacR_HPE1313A:0_Ch55 : 22.4121
HacR_HPE1313A:0_Ch54 : -0.79834
HacR_alignROLL : -0.317084
HacR_alignPITCH : -0.00959614
HacR_alignHPT : -1.37456
HacL_HPM_LVDT:VALr : -8439
HacL_VPM_LVDT:VALr : 1646
HacL_HPE1313A:0_Ch58 : -0.168457
HacL_HPE1313A:0_Ch55 : 23.584
HacL_HPE1313A:0_Ch54 : -0.034668
HacL_alignROLL : 0.308551
HacL_alignPITCH : -0.114723
HacL_alignHPT : 5.54713
Right Arm Angle Floor Angle : 16
Right Arm Angle Vernier : -34.2
Right Arm Scattering Angle : 16.0092
Left Arm Angle Floor Angle : 16
Left Arm Angle Vernier : 31.5
Left Arm Scattering Angle : 15.965
Wien angle :
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 35
Laser power Hall A : 63
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88