User name adev
Log entry time 01:32:48 on September 30, 2000
Entry number 48585
keyword=End_of_Run_1106
End-of-run EPICS data for Run Number 1106 at Sat Sep 30 01:32:33 EDT 2000
Right Arm D1 momentum : 0.854999
Right Arm arm angle : 16.0091
Left Arm D1 momentum : 0.855009
Left Arm arm angle : 15.965
Tiefenbach Hall A energy : 825.103
Right Arm arm mispointing (HPT) : -1.36771
Left Arm arm mispointing (HPT) : 5.53797
Right Arm Q1 power supply current : 642.95
Right Arm Q1 momentum : 0.855061
Right Arm Q1 gauss meter : -0.01612
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 367.956
Right Arm Q2 momentum : 0.854981
Right Arm Q2 gauss meter : 0.19352
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 293.887
Right Arm D1 momentum : 0.855
Right Arm D1 NMR : 0.31728
Right Arm Q3 power supply current : 340.393
Right Arm Q3 momentum : 0.855456
Right Arm Q3 gauss meter : 0.15258
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 642.985
Left Arm Q1 momentum : 0.854656
Left Arm Q1 gauss meter : -0.05442
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 368.28
Left Arm Q2 momentum : 0.855271
Left Arm Q2 gauss meter : 0.19475
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 285.644
Left Arm D1 momentum : 0.855009
Left Arm D1 NMR : 0.316587
Left Arm Q3 power supply current : 340.39
Left Arm Q3 momentum : 0.854995
Left Arm Q3 gauss meter : -0.16961
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 5.63785
Current on Unser monitor : 6.79651
Current on Upstream bcm : 5.70429
Current on Downstream bcm : 5.5714
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 5.69802
MBSY1c Hall A Beam energy : 825.959
MBSY1c magnet current (amp) : 34.0388
MBSY1c Bdl : 206119
MBSY3c Hall C Beam energy : 2392.25
Tiefenbach Hall A energy : 825.103
Tiefenbach Hall C energy : 2383.96
Delta(E)/E width (MV_AI_DXWID) : 4.15145
IPM1C12.XPOS : 0.609025
IPM1H04A.XPOS : -1.32705
IPM1H04A.YPOS : 1.09692
IPM1H04B.XPOS : -0.930205
IPM1H04B.YPOS : 1.34143
Right Arm Arm Collimator : 0.61499
Left Arm Arm Collimator : 0.616943
HacR_HPM_LVDT:VALr : -1278
HacR_VPM_LVDT:VALr : -1344
HacR_HPE1313A:0_Ch58 : -0.54541
HacR_HPE1313A:0_Ch55 : 22.2656
HacR_HPE1313A:0_Ch54 : -0.799805
HacR_alignROLL : -0.319231
HacR_alignPITCH : -0.0111926
HacR_alignHPT : -1.36774
HacL_HPM_LVDT:VALr : -8429
HacL_VPM_LVDT:VALr : 1673
HacL_HPE1313A:0_Ch58 : -0.168457
HacL_HPE1313A:0_Ch55 : 23.584
HacL_HPE1313A:0_Ch54 : -0.034668
HacL_alignROLL : 0.308551
HacL_alignPITCH : -0.114723
HacL_alignHPT : 5.53708
haBDSPOS : 732012
haL1_Fan_frequency_R : 67
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haH2_P_Fill_Target_R : 25.12
haH2_P_Exhaust_R : 25.43
haH2_P_Fill_Bottle_R : 25.51
haH2_DP_Fill_Exhaust_R : 0
haD2_P_Fill_Target_R : 0
haD2_P_Exhaust_R : 0
haD2_P_Fill_Bottle_R : 0
haD2_DP_Fill_Exhaust_R : 27.425
haSC200_6_Sensor_1_R : 242.85
haSC200_6_Sensor_2_R : 223.14
haSC200_6_Sensor_3_R : -0.07
haSC200_6_Sensor_4_R : 35.74
haHe_Omega_DPG_Sensor_R : 5.723
haITC502_1_Sensor_1_R : 5.79
haITC502_1_Sensor_2_R : 5.78
haITC502_1_Sensor_3_R : 5.86999
haITC502_2_Sensor_1_R : 94.98
haITC502_2_Sensor_2_R : 94.98
haITC502_2_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 6
haITC502_4_Sensor_2_R : 115.3
haITC502_4_Sensor_3_R : 78.5
haITC502_5_Sensor_1_R : 5.81
haITC502_5_Sensor_2_R : 5.8
haITC502_5_Sensor_3_R : 204.3
haITC502_6_Sensor_1_R : 5.81
haITC502_6_Sensor_2_R : 5.8
haITC502_6_Sensor_3_R : 27.28
Right Arm VDC Top HV :
Right Arm VDC Bottom HV :
Left Arm VDC Top HV :
Left Arm VDC Bottom HV :
Right Arm Arm Collimator : 0.61499
Left Arm Arm Collimator : 0.616992
Wien angle :
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 35
Laser power Hall A : 63