User name adev
Log entry time 02:06:51 on September 30, 2000
Entry number 48591
keyword=End_of_Run_1110
End-of-run EPICS data for Run Number 1110 at Sat Sep 30 02:06:36 EDT 2000
Right Arm D1 momentum : 0.855
Right Arm arm angle : 16.0092
Left Arm D1 momentum : 0.855006
Left Arm arm angle : 15.9651
Tiefenbach Hall A energy : 825.103
Right Arm arm mispointing (HPT) : -1.37355
Left Arm arm mispointing (HPT) : 5.52691
Right Arm Q1 power supply current : 642.845
Right Arm Q1 momentum : 0.854921
Right Arm Q1 gauss meter : -0.016113
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 368.016
Right Arm Q2 momentum : 0.85512
Right Arm Q2 gauss meter : 0.1936
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 293.886
Right Arm D1 momentum : 0.855
Right Arm D1 NMR : 0.31728
Right Arm Q3 power supply current : 340.218
Right Arm Q3 momentum : 0.855016
Right Arm Q3 gauss meter : 0.15261
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 642.985
Left Arm Q1 momentum : 0.854656
Left Arm Q1 gauss meter : -0.05439
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 368.3
Left Arm Q2 momentum : 0.854784
Left Arm Q2 gauss meter : 0.19481
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 285.65
Left Arm D1 momentum : 0.855006
Left Arm D1 NMR : 0.316586
Left Arm Q3 power supply current : 340.409
Left Arm Q3 momentum : 0.855045
Left Arm Q3 gauss meter : -0.16966
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 5.72548
Current on Unser monitor : 7.20984
Current on Upstream bcm : 5.79354
Current on Downstream bcm : 5.65742
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 5.78927
MBSY1c Hall A Beam energy : 825.959
MBSY1c magnet current (amp) : 34.0388
MBSY1c Bdl : 206119
MBSY3c Hall C Beam energy : 2392.25
Tiefenbach Hall A energy : 825.103
Tiefenbach Hall C energy : 2383.96
Delta(E)/E width (MV_AI_DXWID) : 4.14727
IPM1C12.XPOS : 0.43097
IPM1H04A.XPOS : -1.43359
IPM1H04A.YPOS : 0.879719
IPM1H04B.XPOS : -0.0380293
IPM1H04B.YPOS : 1.04838
Right Arm Arm Collimator : 0.61499
Left Arm Arm Collimator : 0.616943
HacR_HPM_LVDT:VALr : -1273
HacR_VPM_LVDT:VALr : -1322
HacR_HPE1313A:0_Ch58 : -0.545898
HacR_HPE1313A:0_Ch55 : 22.2656
HacR_HPE1313A:0_Ch54 : -0.800781
HacR_alignROLL : -0.320275
HacR_alignPITCH : -0.00977993
HacR_alignHPT : -1.37386
HacL_HPM_LVDT:VALr : -8419
HacL_VPM_LVDT:VALr : 1684
HacL_HPE1313A:0_Ch58 : -0.169434
HacL_HPE1313A:0_Ch55 : 23.4375
HacL_HPE1313A:0_Ch54 : -0.034668
HacL_alignROLL : 0.308863
HacL_alignPITCH : -0.113265
HacL_alignHPT : 5.52575
haBDSPOS : 732012
haL1_Fan_frequency_R : 69
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haH2_P_Fill_Target_R : 25.1
haH2_P_Exhaust_R : 25.46
haH2_P_Fill_Bottle_R : 25.52
haH2_DP_Fill_Exhaust_R : 0
haD2_P_Fill_Target_R : 0
haD2_P_Exhaust_R : 0
haD2_P_Fill_Bottle_R : 0
haD2_DP_Fill_Exhaust_R : 27.459
haSC200_6_Sensor_1_R : 242.46
haSC200_6_Sensor_2_R : 223.42
haSC200_6_Sensor_3_R : -0.25
haSC200_6_Sensor_4_R : 35.67
haHe_Omega_DPG_Sensor_R : 5.713
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.79
haITC502_1_Sensor_3_R : 5.86999
haITC502_2_Sensor_1_R : 94.98
haITC502_2_Sensor_2_R : 94.98
haITC502_2_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 6
haITC502_4_Sensor_2_R : 114.3
haITC502_4_Sensor_3_R : 78.3
haITC502_5_Sensor_1_R : 5.82
haITC502_5_Sensor_2_R : 5.81
haITC502_5_Sensor_3_R : 204.3
haITC502_6_Sensor_1_R : 5.82
haITC502_6_Sensor_2_R : 5.81
haITC502_6_Sensor_3_R : 27.26
Right Arm VDC Top HV :
Right Arm VDC Bottom HV :
Left Arm VDC Top HV :
Left Arm VDC Bottom HV :
Right Arm Arm Collimator : 0.614893
Left Arm Arm Collimator : 0.616895
Wien angle :
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 35
Laser power Hall A : 63