Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 03:16:37 on September 30, 2000
Entry number 48611
keyword=End_of_Run_1120
End-of-run EPICS data for Run Number 1120 at Sat Sep 30 03:16:22 EDT 2000
Right Arm D1 momentum : 0.855
Right Arm arm angle : 16.0091
Left Arm D1 momentum : 0.855008
Left Arm arm angle : 15.9651
Tiefenbach Hall A energy : 825.103
Right Arm arm mispointing (HPT) : -1.36687
Left Arm arm mispointing (HPT) : 5.52266
Right Arm Q1 power supply current : 642.88
Right Arm Q1 momentum : 0.854968
Right Arm Q1 gauss meter : -0.01612
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 368.037
Right Arm Q2 momentum : 0.85528
Right Arm Q2 gauss meter : 0.1936
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 293.887
Right Arm D1 momentum : 0.855
Right Arm D1 NMR : 0.31728
Right Arm Q3 power supply current : 340.486
Right Arm Q3 momentum : 0.855688
Right Arm Q3 gauss meter : 0.15261
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 643.055
Left Arm Q1 momentum : 0.854749
Left Arm Q1 gauss meter : -0.05442
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 367.885
Left Arm Q2 momentum : 0.854355
Left Arm Q2 gauss meter : 0.19467
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 285.65
Left Arm D1 momentum : 0.855007
Left Arm D1 NMR : 0.316586
Left Arm Q3 power supply current : 340.401
Left Arm Q3 momentum : 0.855025
Left Arm Q3 gauss meter : -0.16962
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 5.73583
Current on Unser monitor : 7.40185
Current on Upstream bcm : 5.80528
Current on Downstream bcm : 5.66638
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 5.78394
MBSY1c Hall A Beam energy : 825.959
MBSY1c magnet current (amp) : 34.0388
MBSY1c Bdl : 206119
MBSY3c Hall C Beam energy : 2392.25
Tiefenbach Hall A energy : 825.103
Tiefenbach Hall C energy : 2383.96
Delta(E)/E width (MV_AI_DXWID) : 4.20584
IPM1C12.XPOS : 0.320405
IPM1H04A.XPOS : 0.551885
IPM1H04A.YPOS : 0.0226593
IPM1H04B.XPOS : 1.85374
IPM1H04B.YPOS : -0.0328008
Right Arm Arm Collimator : 0.61499
Left Arm Arm Collimator : 0.617041
HacR_HPM_LVDT:VALr : -1277
HacR_VPM_LVDT:VALr : -1314
HacR_HPE1313A:0_Ch58 : -0.545898
HacR_HPE1313A:0_Ch55 : 22.2168
HacR_HPE1313A:0_Ch54 : -0.800781
HacR_alignROLL : -0.320827
HacR_alignPITCH : -0.00971371
HacR_alignHPT : -1.36795
HacL_HPM_LVDT:VALr : -8416
HacL_VPM_LVDT:VALr : 1686
HacL_HPE1313A:0_Ch58 : -0.167969
HacL_HPE1313A:0_Ch55 : 23.4863
HacL_HPE1313A:0_Ch54 : -0.0341797
HacL_alignROLL : 0.308323
HacL_alignPITCH : -0.114937
HacL_alignHPT : 5.52266
haBDSPOS : 732012
haL1_Fan_frequency_R : 65
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haH2_P_Fill_Target_R : 25.18
haH2_P_Exhaust_R : 25.47
haH2_P_Fill_Bottle_R : 25.55
haH2_DP_Fill_Exhaust_R : 0
haD2_P_Fill_Target_R : 0
haD2_P_Exhaust_R : 0
haD2_P_Fill_Bottle_R : 0
haD2_DP_Fill_Exhaust_R : 27.398
haSC200_6_Sensor_1_R : 242.51
haSC200_6_Sensor_2_R : 223.1
haSC200_6_Sensor_3_R : -0.2
haSC200_6_Sensor_4_R : 35.67
haHe_Omega_DPG_Sensor_R : 5.622
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.79
haITC502_1_Sensor_3_R : 5.86999
haITC502_2_Sensor_1_R : 94.98
haITC502_2_Sensor_2_R : 94.98
haITC502_2_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 6
haITC502_4_Sensor_2_R : 112.6
haITC502_4_Sensor_3_R : 78.4
haITC502_5_Sensor_1_R : 5.81
haITC502_5_Sensor_2_R : 5.8
haITC502_5_Sensor_3_R : 204.1
haITC502_6_Sensor_1_R : 5.81
haITC502_6_Sensor_2_R : 5.8
haITC502_6_Sensor_3_R : 27.24
Right Arm VDC Top HV :
Right Arm VDC Bottom HV :
Left Arm VDC Top HV :
Left Arm VDC Bottom HV :
Right Arm Arm Collimator : 0.614893
Left Arm Arm Collimator : 0.616943
Wien angle :
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 35
Laser power Hall A : 63