User name adev
Log entry time 11:53:32 on September 30, 2000
Entry number 48680
keyword=End_of_Run_1151
End-of-run EPICS data for Run Number 1151 at Sat Sep 30 11:53:14 EDT 2000
Right Arm D1 momentum : 0.838
Right Arm arm angle : 16.0092
Left Arm D1 momentum : 0.837999
Left Arm arm angle : 15.9651
Tiefenbach Hall A energy : 825.102
Right Arm arm mispointing (HPT) : -1.3803
Left Arm arm mispointing (HPT) : 5.52348
Right Arm Q1 power supply current : 630.105
Right Arm Q1 momentum : 0.837978
Right Arm Q1 gauss meter : -0.015805
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 360.709
Right Arm Q2 momentum : 0.838143
Right Arm Q2 gauss meter : 0.18969
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 287.719
Right Arm D1 momentum : 0.838
Right Arm D1 NMR : 0.310972
Right Arm Q3 power supply current : 333.222
Right Arm Q3 momentum : 0.837432
Right Arm Q3 gauss meter : 0.14951
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 630.455
Left Arm Q1 momentum : 0.838002
Left Arm Q1 gauss meter : -0.05334
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 360.873
Left Arm Q2 momentum : 0.838071
Left Arm Q2 gauss meter : 0.19088
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 279.914
Left Arm D1 momentum : 0.837999
Left Arm D1 NMR : 0.310293
Left Arm Q3 power supply current : 333.634
Left Arm Q3 momentum : 0.838027
Left Arm Q3 gauss meter : -0.16627
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 4.85829
Current on Unser monitor : 5.71721
Current on Upstream bcm : 4.89945
Current on Downstream bcm : 4.81713
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 4.87892
MBSY1c Hall A Beam energy : 825.959
MBSY1c magnet current (amp) : 34.0388
MBSY1c Bdl : 206119
MBSY3c Hall C Beam energy : 2392.25
Tiefenbach Hall A energy : 825.093
Tiefenbach Hall C energy : 2383.96
Delta(E)/E width (MV_AI_DXWID) : 4.12088
IPM1C12.XPOS : 0.0030455
IPM1H04A.XPOS : -0.747943
IPM1H04A.YPOS : 0.108605
IPM1H04B.XPOS : 0.0166428
IPM1H04B.YPOS : -0.0178126
Right Arm Arm Collimator : 0.865332
Left Arm Arm Collimator : 0.868652
HacR_HPM_LVDT:VALr : -1266
HacR_VPM_LVDT:VALr : -1253
HacR_HPE1313A:0_Ch58 : -0.543457
HacR_HPE1313A:0_Ch55 : 22.2168
HacR_HPE1313A:0_Ch54 : -0.801758
HacR_alignROLL : -0.320885
HacR_alignPITCH : -0.0114425
HacR_alignHPT : -1.38135
HacL_HPM_LVDT:VALr : -8417
HacL_VPM_LVDT:VALr : 1686
HacL_HPE1313A:0_Ch58 : -0.168457
HacL_HPE1313A:0_Ch55 : 23.584
HacL_HPE1313A:0_Ch54 : -0.034668
HacL_alignROLL : 0.308475
HacL_alignPITCH : -0.115085
HacL_alignHPT : 5.5237
haBDSPOS : 732013
haL1_Fan_frequency_R : 66.5
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haH2_P_Fill_Target_R : 25.38
haH2_P_Exhaust_R : 25.73
haH2_P_Fill_Bottle_R : 25.8
haH2_DP_Fill_Exhaust_R : 0
haD2_P_Fill_Target_R : 0
haD2_P_Exhaust_R : 0
haD2_P_Fill_Bottle_R : 0
haD2_DP_Fill_Exhaust_R : 27.325
haSC200_6_Sensor_1_R : 242.8
haSC200_6_Sensor_2_R : 223.37
haSC200_6_Sensor_3_R : -0.1
haSC200_6_Sensor_4_R : 35.72
haHe_Omega_DPG_Sensor_R : 5.751
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.79
haITC502_1_Sensor_3_R : 5.86999
haITC502_2_Sensor_1_R : 94.98
haITC502_2_Sensor_2_R : 94.98
haITC502_2_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 6
haITC502_4_Sensor_2_R : 107.4
haITC502_4_Sensor_3_R : 78.7
haITC502_5_Sensor_1_R : 5.81
haITC502_5_Sensor_2_R : 5.81
haITC502_5_Sensor_3_R : 203.6
haITC502_6_Sensor_1_R : 5.82
haITC502_6_Sensor_2_R : 5.8
haITC502_6_Sensor_3_R : 27.24
Right Arm VDC Top HV :
Right Arm VDC Bottom HV :
Left Arm VDC Top HV :
Left Arm VDC Bottom HV :
Right Arm Arm Collimator : 0.865381
Left Arm Arm Collimator : 0.868652
Wien angle :
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 80
Laser power Hall A : 63