Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 14:43:42 on September 30, 2000
Entry number 48698
keyword=End_of_Run_1160
End-of-run EPICS data for Run Number 1160 at Sat Sep 30 14:38:51 EDT 2000
Right Arm D1 momentum : 0.821
Right Arm arm angle : 16.0093
Left Arm D1 momentum : 0.820992
Left Arm arm angle : 15.965
Tiefenbach Hall A energy : 825.091
Right Arm arm mispointing (HPT) : -1.38524
Left Arm arm mispointing (HPT) : 5.54531
Right Arm Q1 power supply current : 617.26
Right Arm Q1 momentum : 0.820896
Right Arm Q1 gauss meter : -0.015478
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 353.421
Right Arm Q2 momentum : 0.821208
Right Arm Q2 gauss meter : 0.18597
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 281.69
Right Arm D1 momentum : 0.821
Right Arm D1 NMR : 0.304663
Right Arm Q3 power supply current : 326.828
Right Arm Q3 momentum : 0.821364
Right Arm Q3 gauss meter : 0.14653
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 617.68
Left Arm Q1 momentum : 0.821021
Left Arm Q1 gauss meter : -0.05229
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 353.395
Left Arm Q2 momentum : 0.820703
Left Arm Q2 gauss meter : 0.18699
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 274.092
Left Arm D1 momentum : 0.820992
Left Arm D1 NMR : 0.304001
Left Arm Q3 power supply current : 326.907
Left Arm Q3 momentum : 0.821131
Left Arm Q3 gauss meter : -0.16292
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 4.71702
Current on Unser monitor : 5.23489
Current on Upstream bcm : 4.77742
Current on Downstream bcm : 4.65661
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 4.7405
MBSY1c Hall A Beam energy : 825.959
MBSY1c magnet current (amp) : 34.0388
MBSY1c Bdl : 206119
MBSY3c Hall C Beam energy : 2392.25
Tiefenbach Hall A energy : 825.091
Tiefenbach Hall C energy : 2383.96
Delta(E)/E width (MV_AI_DXWID) : 4.03052
IPM1C12.XPOS : 0.0038408
IPM1H04A.XPOS : -0.738837
IPM1H04A.YPOS : 0.25571
IPM1H04B.XPOS : 0.0397982
IPM1H04B.YPOS : 0.157757
Right Arm Arm Collimator : 0.364063
Left Arm Arm Collimator : 0.61709
HacR_HPM_LVDT:VALr : -1264
HacR_VPM_LVDT:VALr : -1199
HacR_HPE1313A:0_Ch58 : -0.544922
HacR_HPE1313A:0_Ch55 : 22.168
HacR_HPE1313A:0_Ch54 : -0.800781
HacR_alignROLL : -0.320392
HacR_alignPITCH : -0.0105449
HacR_alignHPT : -1.38387
HacL_HPM_LVDT:VALr : -8437
HacL_VPM_LVDT:VALr : 1695
HacL_HPE1313A:0_Ch58 : -0.16748
HacL_HPE1313A:0_Ch55 : 23.5352
HacL_HPE1313A:0_Ch54 : -0.0336914
HacL_alignROLL : 0.309945
HacL_alignPITCH : -0.115596
HacL_alignHPT : 5.54534
haBDSPOS : 2.11541e+06
haL1_Fan_frequency_R : 58
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haH2_P_Fill_Target_R : 25.3
haH2_P_Exhaust_R : 25.63
haH2_P_Fill_Bottle_R : 25.72
haH2_DP_Fill_Exhaust_R : 0
haD2_P_Fill_Target_R : 0
haD2_P_Exhaust_R : 0
haD2_P_Fill_Bottle_R : 0
haD2_DP_Fill_Exhaust_R : 27.35
haSC200_6_Sensor_1_R : 243.22
haSC200_6_Sensor_2_R : 223.45
haSC200_6_Sensor_3_R : 0.05
haSC200_6_Sensor_4_R : 35.8
haHe_Omega_DPG_Sensor_R : 5.712
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.79
haITC502_1_Sensor_3_R : 5.87999
haITC502_2_Sensor_1_R : 94.98
haITC502_2_Sensor_2_R : 94.98
haITC502_2_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 6
haITC502_4_Sensor_2_R : 106.6
haITC502_4_Sensor_3_R : 78
haITC502_5_Sensor_1_R : 5.82
haITC502_5_Sensor_2_R : 5.81
haITC502_5_Sensor_3_R : 201.2
haITC502_6_Sensor_1_R : 5.82
haITC502_6_Sensor_2_R : 5.81
haITC502_6_Sensor_3_R : 27.12
Right Arm VDC Top HV :
Right Arm VDC Bottom HV :
Left Arm VDC Top HV :
Left Arm VDC Bottom HV :
Right Arm Arm Collimator : 0.364014
Left Arm Arm Collimator : 0.617041
Wien angle :
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A :
Laser power Hall A : 63