User name adev
Log entry time 15:25:24 on September 30, 2000
Entry number 48704
keyword=End_of_Run_1163
End-of-run EPICS data for Run Number 1163 at Sat Sep 30 15:25:02 EDT 2000
Right Arm D1 momentum : 0.821
Right Arm arm angle : 16.0094
Left Arm D1 momentum : 0.820993
Left Arm arm angle : 15.965
Tiefenbach Hall A energy : 825.089
Right Arm arm mispointing (HPT) : -1.39786
Left Arm arm mispointing (HPT) : 5.54538
Right Arm Q1 power supply current : 617.365
Right Arm Q1 momentum : 0.821035
Right Arm Q1 gauss meter : -0.015489
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 353.271
Right Arm Q2 momentum : 0.820859
Right Arm Q2 gauss meter : 0.18592
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 281.682
Right Arm D1 momentum : 0.820999
Right Arm D1 NMR : 0.304663
Right Arm Q3 power supply current : 326.683
Right Arm Q3 momentum : 0.821
Right Arm Q3 gauss meter : 0.14656
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 617.61
Left Arm Q1 momentum : 0.820928
Left Arm Q1 gauss meter : -0.05226
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 353.484
Left Arm Q2 momentum : 0.820911
Left Arm Q2 gauss meter : 0.18696
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 274.089
Left Arm D1 momentum : 0.820993
Left Arm D1 NMR : 0.304001
Left Arm Q3 power supply current : 326.851
Left Arm Q3 momentum : 0.820988
Left Arm Q3 gauss meter : -0.16293
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 4.61835
Current on Unser monitor : 5.95557
Current on Upstream bcm : 4.70436
Current on Downstream bcm : 4.53233
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 4.65397
MBSY1c Hall A Beam energy : 825.959
MBSY1c magnet current (amp) : 34.0388
MBSY1c Bdl : 206119
MBSY3c Hall C Beam energy : 2392.25
Tiefenbach Hall A energy : 825.089
Tiefenbach Hall C energy : 2383.96
Delta(E)/E width (MV_AI_DXWID) : 4.20932
IPM1C12.XPOS : 0.00638032
IPM1H04A.XPOS : -0.747065
IPM1H04A.YPOS : 0.186703
IPM1H04B.XPOS : 0.0386192
IPM1H04B.YPOS : 0.0549948
Right Arm Arm Collimator : 0.364063
Left Arm Arm Collimator : 0.366016
HacR_HPM_LVDT:VALr : -1252
HacR_VPM_LVDT:VALr : -1186
HacR_HPE1313A:0_Ch58 : -0.544434
HacR_HPE1313A:0_Ch55 : 22.168
HacR_HPE1313A:0_Ch54 : -0.802246
HacR_alignROLL : -0.321871
HacR_alignPITCH : -0.0109937
HacR_alignHPT : -1.39534
HacL_HPM_LVDT:VALr : -8437
HacL_VPM_LVDT:VALr : 1703
HacL_HPE1313A:0_Ch58 : -0.167969
HacL_HPE1313A:0_Ch55 : 23.584
HacL_HPE1313A:0_Ch54 : -0.0336914
HacL_alignROLL : 0.30948
HacL_alignPITCH : -0.115159
HacL_alignHPT : 5.54557
haBDSPOS : 2.50445e+06
haL1_Fan_frequency_R : 65.5
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haH2_P_Fill_Target_R : 25.37
haH2_P_Exhaust_R : 25.7
haH2_P_Fill_Bottle_R : 25.77
haH2_DP_Fill_Exhaust_R : 0
haD2_P_Fill_Target_R : 0
haD2_P_Exhaust_R : 0
haD2_P_Fill_Bottle_R : 0
haD2_DP_Fill_Exhaust_R : 27.419
haSC200_6_Sensor_1_R : 243.25
haSC200_6_Sensor_2_R : 223.37
haSC200_6_Sensor_3_R : 0.02
haSC200_6_Sensor_4_R : 35.77
haHe_Omega_DPG_Sensor_R : 5.758
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.79
haITC502_1_Sensor_3_R : 5.86999
haITC502_2_Sensor_1_R : 94.98
haITC502_2_Sensor_2_R : 94.98
haITC502_2_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 6
haITC502_4_Sensor_2_R : 106.4
haITC502_4_Sensor_3_R : 78.1
haITC502_5_Sensor_1_R : 5.81
haITC502_5_Sensor_2_R : 5.81
haITC502_5_Sensor_3_R : 200.8
haITC502_6_Sensor_1_R : 5.82
haITC502_6_Sensor_2_R : 5.81
haITC502_6_Sensor_3_R : 27.06
Right Arm VDC Top HV :
Right Arm VDC Bottom HV :
Left Arm VDC Top HV :
Left Arm VDC Bottom HV :
Right Arm Arm Collimator : 0.37876
Left Arm Arm Collimator : 0.366064
Wien angle :
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A :
Laser power Hall A : 63