User name adev
Log entry time 15:43:40 on September 30, 2000
Entry number 48707
keyword=Start_Run_1165_Tar=9foil-optics,Type=Optics,Pmom=0.821,Emom=0.821,Ene=826,Angle_e=16.009,Angle_h=15.965
Beginning-of-run EPICS data for Run Number 1165 at Sat Sep 30 15:43:27 EDT 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=100,ps2=290,ps3=100,ps4=1800,ps5=65535,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 617.295
Right Arm Q1 momentum : 0.820942
Right Arm Q1 gauss meter : -0.015489
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 353.282
Right Arm Q2 momentum : 0.821293
Right Arm Q2 gauss meter : 0.18593
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 281.682
Right Arm D1 momentum : 0.820999
Right Arm D1 NMR : 0.304663
Right Arm Q3 power supply current : 326.723
Right Arm Q3 momentum : 0.8211
Right Arm Q3 gauss meter : 0.14649
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 617.61
Left Arm Q1 momentum : 0.820928
Left Arm Q1 gauss meter : -0.05228
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 353.318
Left Arm Q2 momentum : 0.820526
Left Arm Q2 gauss meter : 0.18697
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 274.092
Left Arm D1 momentum : 0.820994
Left Arm D1 NMR : 0.304002
Left Arm Q3 power supply current : 326.855
Left Arm Q3 momentum : 0.821
Left Arm Q3 gauss meter : -0.16291
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 4.76222
Current on Unser monitor : 5.96481
Current on Upstream bcm : 4.84487
Current on Downstream bcm : 4.67956
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 4.81697
Beam energy : 825.959
MBSY1c magnet current (amp) : 34.0388
Radiator 5V Linear Supply :
Radiator Encoder :
haBDSPOS : 2.50445e+06
haL1_Fan_frequency_R : 68.5
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 243.23
haSC200_6_Sensor_2_R : 223.2
haSC200_6_Sensor_3_R : 0.03
haSC200_6_Sensor_4_R : 35.77
haHe_Omega_DPG_Sensor_R : 5.722
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.78
haITC502_1_Sensor_3_R : 5.86999
haITC502_4_Sensor_1_R : 6
haITC502_4_Sensor_2_R : 106.4
haITC502_4_Sensor_3_R : 78.3
haITC502_5_Sensor_1_R : 5.81
haITC502_5_Sensor_2_R : 5.8
haITC502_5_Sensor_3_R : 200.4
haITC502_6_Sensor_1_R : 5.81
haITC502_6_Sensor_2_R : 5.81
haITC502_6_Sensor_3_R : 27.05
Right Arm Arm Collimator : 0.865381
Left Arm Arm Collimator : 0.868652
HacR_HPM_LVDT:VALr : -1224
HacR_VPM_LVDT:VALr : -1185
HacR_HPE1313A:0_Ch58 : -0.544434
HacR_HPE1313A:0_Ch55 : 22.1191
HacR_HPE1313A:0_Ch54 : -0.801758
HacR_alignROLL : -0.320944
HacR_alignPITCH : -0.0104787
HacR_alignHPT : -1.42609
HacL_HPM_LVDT:VALr : -8437
HacL_VPM_LVDT:VALr : 1703
HacL_HPE1313A:0_Ch58 : -0.16748
HacL_HPE1313A:0_Ch55 : 23.584
HacL_HPE1313A:0_Ch54 : -0.0341797
HacL_alignROLL : 0.309404
HacL_alignPITCH : -0.114648
HacL_alignHPT : 5.54449
Right Arm Angle Floor Angle : 16
Right Arm Angle Vernier : -34.2
Right Arm Scattering Angle : 16.0095
Left Arm Angle Floor Angle : 16
Left Arm Angle Vernier : 31.5
Left Arm Scattering Angle : 15.965
Wien angle :
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 80
Laser power Hall A : 63
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88