User name adev
Log entry time 16:56:46 on September 30, 2000
Entry number 48718
keyword=End_of_Run_1169
End-of-run EPICS data for Run Number 1169 at Sat Sep 30 16:56:30 EDT 2000
Right Arm D1 momentum : 0.804999
Right Arm arm angle : 16.0094
Left Arm D1 momentum : 0.804993
Left Arm arm angle : 15.965
Tiefenbach Hall A energy : 824.058
Right Arm arm mispointing (HPT) : -1.40538
Left Arm arm mispointing (HPT) : 5.5478
Right Arm Q1 power supply current : 605.29
Right Arm Q1 momentum : 0.804977
Right Arm Q1 gauss meter : -0.015177
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 346.303
Right Arm Q2 momentum : 0.804668
Right Arm Q2 gauss meter : 0.18226
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 276.051
Right Arm D1 momentum : 0.804999
Right Arm D1 NMR : 0.298725
Right Arm Q3 power supply current : 320.227
Right Arm Q3 momentum : 0.804775
Right Arm Q3 gauss meter : 0.14363
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 605.605
Left Arm Q1 momentum : 0.804971
Left Arm Q1 gauss meter : -0.05126
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 346.66
Left Arm Q2 momentum : 0.804452
Left Arm Q2 gauss meter : 0.18336
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 268.616
Left Arm D1 momentum : 0.804993
Left Arm D1 NMR : 0.298082
Left Arm Q3 power supply current : 320.411
Left Arm Q3 momentum : 0.804813
Left Arm Q3 gauss meter : -0.15968
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 4.72749
Current on Unser monitor : 5.11641
Current on Upstream bcm : 4.81326
Current on Downstream bcm : 4.64171
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 4.76293
MBSY1c Hall A Beam energy : 825.959
MBSY1c magnet current (amp) : 34.0388
MBSY1c Bdl : 206119
MBSY3c Hall C Beam energy : 2392.25
Tiefenbach Hall A energy : 824.136
Tiefenbach Hall C energy : 2383.96
Delta(E)/E width (MV_AI_DXWID) : 4.21651
IPM1C12.XPOS : 4.26681
IPM1H04A.XPOS : -0.669939
IPM1H04A.YPOS : 0.0634114
IPM1H04B.XPOS : 0.191486
IPM1H04B.YPOS : -0.108983
Right Arm Arm Collimator : 0.363965
Left Arm Arm Collimator : 0.365918
HacR_HPM_LVDT:VALr : -1243
HacR_VPM_LVDT:VALr : -1166
HacR_HPE1313A:0_Ch58 : -0.544434
HacR_HPE1313A:0_Ch55 : 22.1191
HacR_HPE1313A:0_Ch54 : -0.801758
HacR_alignROLL : -0.321929
HacR_alignPITCH : -0.0109274
HacR_alignHPT : -1.40762
HacL_HPM_LVDT:VALr : Inf
HacL_VPM_LVDT:VALr : 1712
HacL_HPE1313A:0_Ch58 : -0.168457
HacL_HPE1313A:0_Ch55 : 23.584
HacL_HPE1313A:0_Ch54 : -0.0336914
HacL_alignROLL : 0.308939
HacL_alignPITCH : -0.115085
HacL_alignHPT : 5.54583
haBDSPOS : 2.50445e+06
haL1_Fan_frequency_R : 67.5
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haH2_P_Fill_Target_R : 25.42
haH2_P_Exhaust_R : 25.75
haH2_P_Fill_Bottle_R : 25.85
haH2_DP_Fill_Exhaust_R : 0
haD2_P_Fill_Target_R : 0
haD2_P_Exhaust_R : 0
haD2_P_Fill_Bottle_R : 0
haD2_DP_Fill_Exhaust_R : 27.369
haSC200_6_Sensor_1_R : 243.25
haSC200_6_Sensor_2_R : 223.45
haSC200_6_Sensor_3_R : 0.02
haSC200_6_Sensor_4_R : 35.77
haHe_Omega_DPG_Sensor_R : 5.673
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.79
haITC502_1_Sensor_3_R : 5.86999
haITC502_2_Sensor_1_R : 94.98
haITC502_2_Sensor_2_R : 94.98
haITC502_2_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 6
haITC502_4_Sensor_2_R : 106.1
haITC502_4_Sensor_3_R : 78.4
haITC502_5_Sensor_1_R : 5.82
haITC502_5_Sensor_2_R : 5.81
haITC502_5_Sensor_3_R : 200
haITC502_6_Sensor_1_R : 5.82
haITC502_6_Sensor_2_R : 5.81
haITC502_6_Sensor_3_R : 27.04
Right Arm VDC Top HV :
Right Arm VDC Bottom HV :
Left Arm VDC Top HV :
Left Arm VDC Bottom HV :
Right Arm Arm Collimator : 0.364014
Left Arm Arm Collimator : 0.365918
Wien angle :
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 80
Laser power Hall A : 63