Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 17:50:42 on September 30, 2000
Entry number 48724
keyword=End_of_Run_1171
End-of-run EPICS data for Run Number 1171 at Sat Sep 30 17:50:21 EDT 2000
Right Arm D1 momentum : 0.804999
Right Arm arm angle : 16.0094
Left Arm D1 momentum : 0.804995
Left Arm arm angle : 15.965
Tiefenbach Hall A energy : 825.087
Right Arm arm mispointing (HPT) : -1.40706
Left Arm arm mispointing (HPT) : 5.55004
Right Arm Q1 power supply current : 605.29
Right Arm Q1 momentum : 0.804977
Right Arm Q1 gauss meter : -0.015189
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 346.614
Right Arm Q2 momentum : 0.805392
Right Arm Q2 gauss meter : 0.1823
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 276.058
Right Arm D1 momentum : 0.804999
Right Arm D1 NMR : 0.298725
Right Arm Q3 power supply current : 320.477
Right Arm Q3 momentum : 0.804806
Right Arm Q3 gauss meter : 0.14367
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 605.605
Left Arm Q1 momentum : 0.804971
Left Arm Q1 gauss meter : -0.05125
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 346.621
Left Arm Q2 momentum : 0.804973
Left Arm Q2 gauss meter : 0.18342
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 268.616
Left Arm D1 momentum : 0.804994
Left Arm D1 NMR : 0.298082
Left Arm Q3 power supply current : 320.508
Left Arm Q3 momentum : 0.805057
Left Arm Q3 gauss meter : -0.15968
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 5.41326
Current on Unser monitor : 6.95843
Current on Upstream bcm : 5.47693
Current on Downstream bcm : 5.3496
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 5.47487
MBSY1c Hall A Beam energy : 825.959
MBSY1c magnet current (amp) : 34.0388
MBSY1c Bdl : 206119
MBSY3c Hall C Beam energy : 2392.25
Tiefenbach Hall A energy : 825.087
Tiefenbach Hall C energy : 2383.96
Delta(E)/E width (MV_AI_DXWID) : 4.133
IPM1C12.XPOS : -0.0124594
IPM1H04A.XPOS : -0.738812
IPM1H04A.YPOS : 0.154658
IPM1H04B.XPOS : 0.0132106
IPM1H04B.YPOS : 0.0182808
Right Arm Arm Collimator : 0.615039
Left Arm Arm Collimator : 0.61709
HacR_HPM_LVDT:VALr : -1242
HacR_VPM_LVDT:VALr : -1163
HacR_HPE1313A:0_Ch58 : -0.54541
HacR_HPE1313A:0_Ch55 : 22.1191
HacR_HPE1313A:0_Ch54 : -0.802734
HacR_alignROLL : -0.321929
HacR_alignPITCH : -0.0100299
HacR_alignHPT : -1.40762
HacL_HPM_LVDT:VALr : -8444
HacL_VPM_LVDT:VALr : 1719
HacL_HPE1313A:0_Ch58 : -0.168457
HacL_HPE1313A:0_Ch55 : 23.584
HacL_HPE1313A:0_Ch54 : -0.0336914
HacL_alignROLL : 0.309015
HacL_alignPITCH : -0.114723
HacL_alignHPT : 5.55249
haBDSPOS : 2.11541e+06
haL1_Fan_frequency_R : 64.5
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haH2_P_Fill_Target_R : 25.48
haH2_P_Exhaust_R : 25.79
haH2_P_Fill_Bottle_R : 25.83
haH2_DP_Fill_Exhaust_R : 0
haD2_P_Fill_Target_R : 0
haD2_P_Exhaust_R : 0
haD2_P_Fill_Bottle_R : 0
haD2_DP_Fill_Exhaust_R : 27.406
haSC200_6_Sensor_1_R : 243.28
haSC200_6_Sensor_2_R : 223.37
haSC200_6_Sensor_3_R : 0
haSC200_6_Sensor_4_R : 35.77
haHe_Omega_DPG_Sensor_R : 5.65
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.79
haITC502_1_Sensor_3_R : 5.86999
haITC502_2_Sensor_1_R : 94.98
haITC502_2_Sensor_2_R : 94.98
haITC502_2_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 6
haITC502_4_Sensor_2_R : 106
haITC502_4_Sensor_3_R : 78.3
haITC502_5_Sensor_1_R : 5.82
haITC502_5_Sensor_2_R : 5.81
haITC502_5_Sensor_3_R : 201.5
haITC502_6_Sensor_1_R : 5.82
haITC502_6_Sensor_2_R : 5.81
haITC502_6_Sensor_3_R : 27.1
Right Arm VDC Top HV :
Right Arm VDC Bottom HV :
Left Arm VDC Top HV :
Left Arm VDC Bottom HV :
Right Arm Arm Collimator : 0.615039
Left Arm Arm Collimator : 0.61709
Wien angle :
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 90
Laser power Hall A : 63