Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 22:41:49 on September 30, 2000
Entry number 48785
keyword=Start_Run_1199_Tar=9foil-optics,Type=Optics,Pmom=0.789,Emom=0.789,Ene=826,Angle_e=16.009,Angle_h=15.965
Beginning-of-run EPICS data for Run Number 1199 at Sat Sep 30 22:41:37 EDT 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=150,ps2=390,ps3=150,ps4=2400,ps5=65535,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 593.285
Right Arm Q1 momentum : 0.789011
Right Arm Q1 gauss meter : -0.014886
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 339.561
Right Arm Q2 momentum : 0.789002
Right Arm Q2 gauss meter : 0.17869
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 270.48
Right Arm D1 momentum : 0.788998
Right Arm D1 NMR : 0.292788
Right Arm Q3 power supply current : 313.961
Right Arm Q3 momentum : 0.789028
Right Arm Q3 gauss meter : 0.14081
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 593.635
Left Arm Q1 momentum : 0.78906
Left Arm Q1 gauss meter : -0.05024
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 339.757
Left Arm Q2 momentum : 0.789032
Left Arm Q2 gauss meter : 0.17975
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 263.165
Left Arm D1 momentum : 0.788993
Left Arm D1 NMR : 0.292162
Left Arm Q3 power supply current : 314.114
Left Arm Q3 momentum : 0.788996
Left Arm Q3 gauss meter : -0.15644
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 0.022771
Current on Unser monitor : 0.696218
Current on Upstream bcm : 0.0247583
Current on Downstream bcm : 0.0210483
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 0.00142881
Beam energy : 825.959
MBSY1c magnet current (amp) : 34.0388
Radiator 5V Linear Supply :
Radiator Encoder :
haBDSPOS : 2.50445e+06
haL1_Fan_frequency_R : 67.5
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 243.1
haSC200_6_Sensor_2_R : 223.33
haSC200_6_Sensor_3_R : -0.08
haSC200_6_Sensor_4_R : 35.72
haHe_Omega_DPG_Sensor_R : 5.696
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.79
haITC502_1_Sensor_3_R : 5.86999
haITC502_4_Sensor_1_R : 6
haITC502_4_Sensor_2_R : 105.5
haITC502_4_Sensor_3_R : 78.1
haITC502_5_Sensor_1_R : 5.82
haITC502_5_Sensor_2_R : 5.81
haITC502_5_Sensor_3_R : 200
haITC502_6_Sensor_1_R : 5.82
haITC502_6_Sensor_2_R : 5.81
haITC502_6_Sensor_3_R : 27.01
Right Arm Arm Collimator : 0.614941
Left Arm Arm Collimator : 0.616992
HacR_HPM_LVDT:VALr : -1212
HacR_VPM_LVDT:VALr : -1109
HacR_HPE1313A:0_Ch58 : -0.544922
HacR_HPE1313A:0_Ch55 : 22.0703
HacR_HPE1313A:0_Ch54 : -0.801758
HacR_alignROLL : -0.321495
HacR_alignPITCH : -0.0108612
HacR_alignHPT : -1.44145
HacL_HPM_LVDT:VALr : -8447
HacL_VPM_LVDT:VALr : 1743
HacL_HPE1313A:0_Ch58 : -0.168945
HacL_HPE1313A:0_Ch55 : 23.4863
HacL_HPE1313A:0_Ch54 : -0.0332031
HacL_alignROLL : 0.309328
HacL_alignPITCH : -0.113701
HacL_alignHPT : 5.5557
Right Arm Angle Floor Angle : 16
Right Arm Angle Vernier : -34.2
Right Arm Scattering Angle : 16.0096
Left Arm Angle Floor Angle : 16
Left Arm Angle Vernier : 31.5
Left Arm Scattering Angle : 15.9649
Wien angle :
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 80
Laser power Hall A : 63
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88