User name adev
Log entry time 23:05:13 on September 30, 2000
Entry number 48790
keyword=Start_Run_1201_Tar=9foil-optics,Type=Optics,Pmom=0.789,Emom=0.789,Ene=826,Angle_e=16.009,Angle_h=15.965
Beginning-of-run EPICS data for Run Number 1201 at Sat Sep 30 23:04:58 EDT 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=150,ps2=390,ps3=150,ps4=2400,ps5=65535,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 593.215
Right Arm Q1 momentum : 0.788918
Right Arm Q1 gauss meter : -0.014882
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 339.602
Right Arm Q2 momentum : 0.789098
Right Arm Q2 gauss meter : 0.17872
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 270.488
Right Arm D1 momentum : 0.789001
Right Arm D1 NMR : 0.292789
Right Arm Q3 power supply current : 313.955
Right Arm Q3 momentum : 0.789012
Right Arm Q3 gauss meter : 0.14082
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 593.635
Left Arm Q1 momentum : 0.78906
Left Arm Q1 gauss meter : -0.05025
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 339.92
Left Arm Q2 momentum : 0.78941
Left Arm Q2 gauss meter : 0.17984
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 263.167
Left Arm D1 momentum : 0.788992
Left Arm D1 NMR : 0.292161
Left Arm Q3 power supply current : 314.074
Left Arm Q3 momentum : 0.789018
Left Arm Q3 gauss meter : -0.15644
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 4.95838
Current on Unser monitor : 7.1016
Current on Upstream bcm : 5.01976
Current on Downstream bcm : 4.89699
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 5.03412
Beam energy : 825.959
MBSY1c magnet current (amp) : 34.0388
Radiator 5V Linear Supply :
Radiator Encoder :
haBDSPOS : 2.50445e+06
haL1_Fan_frequency_R : 66
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 243.1
haSC200_6_Sensor_2_R : 223.45
haSC200_6_Sensor_3_R : -0.08
haSC200_6_Sensor_4_R : 35.7
haHe_Omega_DPG_Sensor_R : 5.755
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.79
haITC502_1_Sensor_3_R : 5.87999
haITC502_4_Sensor_1_R : 6
haITC502_4_Sensor_2_R : 105.4
haITC502_4_Sensor_3_R : 78.2
haITC502_5_Sensor_1_R : 5.82
haITC502_5_Sensor_2_R : 5.81
haITC502_5_Sensor_3_R : 199.7
haITC502_6_Sensor_1_R : 5.82
haITC502_6_Sensor_2_R : 5.81
haITC502_6_Sensor_3_R : 27
Right Arm Arm Collimator : 0.865234
Left Arm Arm Collimator : 0.868457
HacR_HPM_LVDT:VALr : -1186
HacR_VPM_LVDT:VALr : -1097
HacR_HPE1313A:0_Ch58 : -0.544434
HacR_HPE1313A:0_Ch55 : 22.0703
HacR_HPE1313A:0_Ch54 : -0.802734
HacR_alignROLL : -0.321988
HacR_alignPITCH : -0.0104124
HacR_alignHPT : -1.47027
HacL_HPM_LVDT:VALr : -8443
HacL_VPM_LVDT:VALr : 1746
HacL_HPE1313A:0_Ch58 : -0.168945
HacL_HPE1313A:0_Ch55 : 23.4863
HacL_HPE1313A:0_Ch54 : -0.0332031
HacL_alignROLL : 0.309869
HacL_alignPITCH : -0.114212
HacL_alignHPT : 5.55208
Right Arm Angle Floor Angle : 16
Right Arm Angle Vernier : -34.2
Right Arm Scattering Angle : 16.0098
Left Arm Angle Floor Angle : 16
Left Arm Angle Vernier : 31.5
Left Arm Scattering Angle : 15.9649
Wien angle :
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 80
Laser power Hall A : 63
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88