Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 01:03:17 on October 1, 2000
Entry number 48810
keyword=End_of_Run_1211
End-of-run EPICS data for Run Number 1211 at Sun Oct 1 01:02:45 EDT 2000
Right Arm D1 momentum : 0.763999
Right Arm arm angle : 16.0097
Left Arm D1 momentum : 0.763986
Left Arm arm angle : 15.9649
Tiefenbach Hall A energy : 825.089
Right Arm arm mispointing (HPT) : -1.45013
Left Arm arm mispointing (HPT) : 5.55432
Right Arm Q1 power supply current : 574.35
Right Arm Q1 momentum : 0.763829
Right Arm Q1 gauss meter : -0.014419
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 328.914
Right Arm Q2 momentum : 0.764264
Right Arm Q2 gauss meter : 0.17304
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 261.834
Right Arm D1 momentum : 0.764002
Right Arm D1 NMR : 0.283512
Right Arm Q3 power supply current : 304.068
Right Arm Q3 momentum : 0.764164
Right Arm Q3 gauss meter : 0.13641
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 574.805
Left Arm Q1 momentum : 0.764031
Left Arm Q1 gauss meter : -0.04865
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 329.082
Left Arm Q2 momentum : 0.764008
Left Arm Q2 gauss meter : 0.17411
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 254.757
Left Arm D1 momentum : 0.763986
Left Arm D1 NMR : 0.28291
Left Arm Q3 power supply current : 304.13
Left Arm Q3 momentum : 0.763919
Left Arm Q3 gauss meter : -0.15148
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 4.75467
Current on Unser monitor : 6.75645
Current on Upstream bcm : 4.79202
Current on Downstream bcm : 4.67463
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 4.74541
MBSY1c Hall A Beam energy : 825.959
MBSY1c magnet current (amp) : 34.0388
MBSY1c Bdl : 206119
MBSY3c Hall C Beam energy : 2392.25
Tiefenbach Hall A energy : 825.089
Tiefenbach Hall C energy : 2383.96
Delta(E)/E width (MV_AI_DXWID) : 4.21153
IPM1C12.XPOS : 0.00282246
IPM1H04A.XPOS : -0.733625
IPM1H04A.YPOS : 0.156563
IPM1H04B.XPOS : -0.0155917
IPM1H04B.YPOS : 0.0113314
Right Arm Arm Collimator : 0.364014
Left Arm Arm Collimator : 0.365967
HacR_HPM_LVDT:VALr : -1205
HacR_VPM_LVDT:VALr : -1072
HacR_HPE1313A:0_Ch58 : -0.544922
HacR_HPE1313A:0_Ch55 : 22.1191
HacR_HPE1313A:0_Ch54 : -0.802734
HacR_alignROLL : -0.322422
HacR_alignPITCH : -0.0104787
HacR_alignHPT : -1.44876
HacL_HPM_LVDT:VALr : -8445
HacL_VPM_LVDT:VALr : 1761
HacL_HPE1313A:0_Ch58 : -0.169434
HacL_HPE1313A:0_Ch55 : 23.4375
HacL_HPE1313A:0_Ch54 : -0.0332031
HacL_alignROLL : 0.310181
HacL_alignPITCH : -0.113627
HacL_alignHPT : 5.55417
haBDSPOS : 2.50445e+06
haL1_Fan_frequency_R : 67
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haH2_P_Fill_Target_R : 25.52
haH2_P_Exhaust_R : 25.85
haH2_P_Fill_Bottle_R : 25.9
haH2_DP_Fill_Exhaust_R : 0
haD2_P_Fill_Target_R : 0
haD2_P_Exhaust_R : 0
haD2_P_Fill_Bottle_R : 0
haD2_DP_Fill_Exhaust_R : 27.385
haSC200_6_Sensor_1_R : 243.03
haSC200_6_Sensor_2_R : 223.38
haSC200_6_Sensor_3_R : -0.1
haSC200_6_Sensor_4_R : 35.67
haHe_Omega_DPG_Sensor_R : 5.687
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.79
haITC502_1_Sensor_3_R : 5.87999
haITC502_2_Sensor_1_R : 94.98
haITC502_2_Sensor_2_R : 94.98
haITC502_2_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 6
haITC502_4_Sensor_2_R : 105.3
haITC502_4_Sensor_3_R : 78.5
haITC502_5_Sensor_1_R : 5.82
haITC502_5_Sensor_2_R : 5.81
haITC502_5_Sensor_3_R : 199.4
haITC502_6_Sensor_1_R : 5.82
haITC502_6_Sensor_2_R : 5.88
haITC502_6_Sensor_3_R : 26.97
Right Arm VDC Top HV :
Right Arm VDC Bottom HV :
Left Arm VDC Top HV :
Left Arm VDC Bottom HV :
Right Arm Arm Collimator : 0.364063
Left Arm Arm Collimator : 0.365869
Wien angle :
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 80
Laser power Hall A : 63