User name adev
Log entry time 01:11:55 on October 1, 2000
Entry number 48811
keyword=Start_Run_1212_Tar=dum-10cm,Type=Optics,Pmom=0.764,Emom=0.764,Ene=826,Angle_e=16.009,Angle_h=15.965
Beginning-of-run EPICS data for Run Number 1212 at Sun Oct 1 01:11:26 EDT 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=2,ps2=1,ps3=2,ps4=700,ps5=65535,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 574.42
Right Arm Q1 momentum : 0.763969
Right Arm Q1 gauss meter : -0.014413
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 328.717
Right Arm Q2 momentum : 0.764019
Right Arm Q2 gauss meter : 0.17303
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 261.826
Right Arm D1 momentum : 0.764
Right Arm D1 NMR : 0.283511
Right Arm Q3 power supply current : 303.864
Right Arm Q3 momentum : 0.763654
Right Arm Q3 gauss meter : 0.13636
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 574.91
Left Arm Q1 momentum : 0.764171
Left Arm Q1 gauss meter : -0.04867
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 328.961
Left Arm Q2 momentum : 0.76396
Left Arm Q2 gauss meter : 0.17412
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 254.758
Left Arm D1 momentum : 0.763988
Left Arm D1 NMR : 0.282911
Left Arm Q3 power supply current : 304.137
Left Arm Q3 momentum : 0.763935
Left Arm Q3 gauss meter : -0.15145
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 4.45304
Current on Unser monitor : 5.89444
Current on Upstream bcm : 4.52658
Current on Downstream bcm : 4.48076
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 4.50478
Beam energy : 825.959
MBSY1c magnet current (amp) : 34.0388
Radiator 5V Linear Supply :
Radiator Encoder :
haBDSPOS : 2.11541e+06
haL1_Fan_frequency_R : 68
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 243
haSC200_6_Sensor_2_R : 223.48
haSC200_6_Sensor_3_R : -0.13
haSC200_6_Sensor_4_R : 35.65
haHe_Omega_DPG_Sensor_R : 5.641
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.79
haITC502_1_Sensor_3_R : 5.86999
haITC502_4_Sensor_1_R : 6
haITC502_4_Sensor_2_R : 105.3
haITC502_4_Sensor_3_R : 78.6
haITC502_5_Sensor_1_R : 5.82
haITC502_5_Sensor_2_R : 5.81
haITC502_5_Sensor_3_R : 199.6
haITC502_6_Sensor_1_R : 5.82
haITC502_6_Sensor_2_R : 5.81
haITC502_6_Sensor_3_R : 26.98
Right Arm Arm Collimator : 0.363965
Left Arm Arm Collimator : 0.365967
HacR_HPM_LVDT:VALr : -1208
HacR_VPM_LVDT:VALr : -1069
HacR_HPE1313A:0_Ch58 : -0.544434
HacR_HPE1313A:0_Ch55 : 22.0215
HacR_HPE1313A:0_Ch54 : -0.803223
HacR_alignROLL : -0.322973
HacR_alignPITCH : -0.0104124
HacR_alignHPT : -1.44509
HacL_HPM_LVDT:VALr : -8444
HacL_VPM_LVDT:VALr : 1765
HacL_HPE1313A:0_Ch58 : -0.168457
HacL_HPE1313A:0_Ch55 : 23.4375
HacL_HPE1313A:0_Ch54 : -0.0327148
HacL_alignROLL : 0.310181
HacL_alignPITCH : -0.1145
HacL_alignHPT : 5.55305
Right Arm Angle Floor Angle : 16
Right Arm Angle Vernier : -34.2
Right Arm Scattering Angle : 16.0097
Left Arm Angle Floor Angle : 16
Left Arm Angle Vernier : 31.5
Left Arm Scattering Angle : 15.9649
Wien angle :
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 80
Laser power Hall A : 63
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88