User name adev
Log entry time 01:58:23 on October 1, 2000
Entry number 48818
keyword=End_of_Run_1215
End-of-run EPICS data for Run Number 1215 at Sun Oct 1 01:57:53 EDT 2000
Right Arm D1 momentum : 0.763999
Right Arm arm angle : 16.0099
Left Arm D1 momentum : 0.763989
Left Arm arm angle : 15.965
Tiefenbach Hall A energy : 823.893
Right Arm arm mispointing (HPT) : -1.47751
Left Arm arm mispointing (HPT) : 5.54657
Right Arm Q1 power supply current : 574.42
Right Arm Q1 momentum : 0.763923
Right Arm Q1 gauss meter : -0.014423
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 328.988
Right Arm Q2 momentum : 0.764434
Right Arm Q2 gauss meter : 0.17307
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 261.825
Right Arm D1 momentum : 0.763999
Right Arm D1 NMR : 0.283511
Right Arm Q3 power supply current : 303.964
Right Arm Q3 momentum : 0.763904
Right Arm Q3 gauss meter : 0.13639
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 574.91
Left Arm Q1 momentum : 0.764171
Left Arm Q1 gauss meter : -0.04868
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 329.262
Left Arm Q2 momentum : 0.764658
Left Arm Q2 gauss meter : 0.17416
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 254.757
Left Arm D1 momentum : 0.763989
Left Arm D1 NMR : 0.282911
Left Arm Q3 power supply current : 304.18
Left Arm Q3 momentum : 0.764043
Left Arm Q3 gauss meter : -0.15144
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 0.712567
Current on Unser monitor : 2.26639
Current on Upstream bcm : 0.722518
Current on Downstream bcm : 0.702616
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 0.00142881
MBSY1c Hall A Beam energy : 825.959
MBSY1c magnet current (amp) : 34.0388
MBSY1c Bdl : 206119
MBSY3c Hall C Beam energy : 2392.25
Tiefenbach Hall A energy : 823.937
Tiefenbach Hall C energy : 2383.96
Delta(E)/E width (MV_AI_DXWID) : 4.05861
IPM1C12.XPOS : 3.58677
IPM1H04A.XPOS : -0.734961
IPM1H04A.YPOS : 0.131694
IPM1H04B.XPOS : -0.0164246
IPM1H04B.YPOS : -0.0298347
Right Arm Arm Collimator : 0.865381
Left Arm Arm Collimator : 0.868701
HacR_HPM_LVDT:VALr : -1179
HacR_VPM_LVDT:VALr : -1070
HacR_HPE1313A:0_Ch58 : -0.544922
HacR_HPE1313A:0_Ch55 : 22.0215
HacR_HPE1313A:0_Ch54 : -0.802246
HacR_alignROLL : -0.322973
HacR_alignPITCH : -0.0108612
HacR_alignHPT : -1.47755
HacL_HPM_LVDT:VALr : -8438
HacL_VPM_LVDT:VALr : 1765
HacL_HPE1313A:0_Ch58 : -0.168945
HacL_HPE1313A:0_Ch55 : 23.4863
HacL_HPE1313A:0_Ch54 : -0.0336914
HacL_alignROLL : 0.309404
HacL_alignPITCH : -0.114212
HacL_alignHPT : 5.54672
haBDSPOS : 732013
haL1_Fan_frequency_R : 68.5
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haH2_P_Fill_Target_R : 25.52
haH2_P_Exhaust_R : 25.86
haH2_P_Fill_Bottle_R : 25.92
haH2_DP_Fill_Exhaust_R : 0
haD2_P_Fill_Target_R : 0
haD2_P_Exhaust_R : 0
haD2_P_Fill_Bottle_R : 0
haD2_DP_Fill_Exhaust_R : 27.456
haSC200_6_Sensor_1_R : 243
haSC200_6_Sensor_2_R : 223.37
haSC200_6_Sensor_3_R : -0.15
haSC200_6_Sensor_4_R : 35.65
haHe_Omega_DPG_Sensor_R : 5.695
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.79
haITC502_1_Sensor_3_R : 5.87999
haITC502_2_Sensor_1_R : 94.98
haITC502_2_Sensor_2_R : 94.98
haITC502_2_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 6
haITC502_4_Sensor_2_R : 105.3
haITC502_4_Sensor_3_R : 78.5
haITC502_5_Sensor_1_R : 5.82
haITC502_5_Sensor_2_R : 5.81
haITC502_5_Sensor_3_R : 202.2
haITC502_6_Sensor_1_R : 5.82
haITC502_6_Sensor_2_R : 5.81
haITC502_6_Sensor_3_R : 27.1
Right Arm VDC Top HV :
Right Arm VDC Bottom HV :
Left Arm VDC Top HV :
Left Arm VDC Bottom HV :
Right Arm Arm Collimator : 0.86543
Left Arm Arm Collimator : 0.868652
Wien angle :
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 80
Laser power Hall A : 63