User name adev
Log entry time 09:35:48 on October 1, 2000
Entry number 48869
keyword=Start_Run_1233_Tar=4He-10cm,Type=Elastic,Pmom=0.80078,Emom=0.68391,Ene=826,Angle_e=39.982,Angle_h=29.979
Beginning-of-run EPICS data for Run Number 1233 at Sun Oct 1 09:35:35 EDT 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=2,ps2=1,ps3=2,ps4=20,ps5=1000,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 514.22
Right Arm Q1 momentum : 0.683955
Right Arm Q1 gauss meter : -0.012924
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 294.264
Right Arm Q2 momentum : 0.68375
Right Arm Q2 gauss meter : 0.155
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 234.226
Right Arm D1 momentum : 0.68391
Right Arm D1 NMR : 0.253791
Right Arm Q3 power supply current : 272.09
Right Arm Q3 momentum : 0.6838
Right Arm Q3 gauss meter : 0.1221
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 602.175
Left Arm Q1 momentum : 0.800412
Left Arm Q1 gauss meter : -0.05097
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 345.053
Left Arm Q2 momentum : 0.801332
Left Arm Q2 gauss meter : 0.18246
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 267.345
Left Arm D1 momentum : 0.800784
Left Arm D1 NMR : 0.296524
Left Arm Q3 power supply current : 318.803
Left Arm Q3 momentum : 0.800773
Left Arm Q3 gauss meter : -0.15885
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 2.24549
Current on Unser monitor : 3.64316
Current on Upstream bcm : 2.32839
Current on Downstream bcm : 2.16259
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 2.24271
Beam energy : 825.959
MBSY1c magnet current (amp) : 34.0388
Radiator 5V Linear Supply :
Radiator Encoder :
haBDSPOS : 6.517e+06
haL1_Fan_frequency_R : 67
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 243.12
haSC200_6_Sensor_2_R : 225.62
haSC200_6_Sensor_3_R : -0.13
haSC200_6_Sensor_4_R : 35.65
haHe_Omega_DPG_Sensor_R : 5.65
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.79
haITC502_1_Sensor_3_R : 5.87999
haITC502_4_Sensor_1_R : 6
haITC502_4_Sensor_2_R : 144.6
haITC502_4_Sensor_3_R : 98.8
haITC502_5_Sensor_1_R : 5.82
haITC502_5_Sensor_2_R : 5.81
haITC502_5_Sensor_3_R : 198.1
haITC502_6_Sensor_1_R : 5.83
haITC502_6_Sensor_2_R : 5.85
haITC502_6_Sensor_3_R : 26.87
Right Arm Arm Collimator : 0.615088
Left Arm Arm Collimator : 0.617041
HacR_HPM_LVDT:VALr : -4675
HacR_VPM_LVDT:VALr : 52
HacR_HPE1313A:0_Ch58 : -0.550293
HacR_HPE1313A:0_Ch55 : 21.9727
HacR_HPE1313A:0_Ch54 : -0.911133
HacR_alignROLL : -0.431508
HacR_alignPITCH : -0.00534377
HacR_alignHPT : 2.44693
HacL_HPM_LVDT:VALr : -6519
HacL_VPM_LVDT:VALr : 841
HacL_HPE1313A:0_Ch58 : -0.169922
HacL_HPE1313A:0_Ch55 : 23.4375
HacL_HPE1313A:0_Ch54 : -0.288574
HacL_alignROLL : 0.0764755
HacL_alignPITCH : -0.0923517
HacL_alignHPT : 3.5259
Right Arm Angle Floor Angle : 40
Right Arm Angle Vernier : -34.5
Right Arm Scattering Angle : 39.9816
Left Arm Angle Floor Angle : 30
Left Arm Angle Vernier : 31.5
Left Arm Scattering Angle : 29.9787
Wien angle :
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 97
Laser power Hall A : 63
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88