User name adev
Log entry time 10:51:14 on October 1, 2000
Entry number 48880
keyword=Start_Run_1237_Tar=4He-10cm,Type=Elastic,Pmom=0.80078,Emom=0.68391,Ene=826,Angle_e=39.982,Angle_h=29.979
Beginning-of-run EPICS data for Run Number 1237 at Sun Oct 1 10:48:47 EDT 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=7,ps2=1,ps3=7,ps4=25,ps5=1000,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 514.29
Right Arm Q1 momentum : 0.683955
Right Arm Q1 gauss meter : -0.012921
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 294.456
Right Arm Q2 momentum : 0.684196
Right Arm Q2 gauss meter : 0.15494
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 234.225
Right Arm D1 momentum : 0.68391
Right Arm D1 NMR : 0.253791
Right Arm Q3 power supply current : 272.084
Right Arm Q3 momentum : 0.683785
Right Arm Q3 gauss meter : 0.12204
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 602.245
Left Arm Q1 momentum : 0.800505
Left Arm Q1 gauss meter : -0.05098
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 344.847
Left Arm Q2 momentum : 0.800852
Left Arm Q2 gauss meter : 0.1824
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 267.345
Left Arm D1 momentum : 0.800784
Left Arm D1 NMR : 0.296524
Left Arm Q3 power supply current : 318.852
Left Arm Q3 momentum : 0.800897
Left Arm Q3 gauss meter : -0.15886
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 9.94096
Current on Unser monitor : 12.1314
Current on Upstream bcm : 10.0554
Current on Downstream bcm : 9.8265
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 10.0734
Beam energy : 825.959
MBSY1c magnet current (amp) : 34.0388
Radiator 5V Linear Supply :
Radiator Encoder :
haBDSPOS : 6.517e+06
haL1_Fan_frequency_R : 65
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 243.15
haSC200_6_Sensor_2_R : 225.77
haSC200_6_Sensor_3_R : -0.15
haSC200_6_Sensor_4_R : 35.65
haHe_Omega_DPG_Sensor_R : 5.684
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.78
haITC502_1_Sensor_3_R : 5.88999
haITC502_4_Sensor_1_R : 6
haITC502_4_Sensor_2_R : 150.8
haITC502_4_Sensor_3_R : 99.8
haITC502_5_Sensor_1_R : 5.82
haITC502_5_Sensor_2_R : 5.81
haITC502_5_Sensor_3_R : 197.8
haITC502_6_Sensor_1_R : 5.84
haITC502_6_Sensor_2_R : 5.85
haITC502_6_Sensor_3_R : 26.85
Right Arm Arm Collimator : 0.61499
Left Arm Arm Collimator : 0.617041
HacR_HPM_LVDT:VALr : -4684
HacR_VPM_LVDT:VALr : 66
HacR_HPE1313A:0_Ch58 : -0.549316
HacR_HPE1313A:0_Ch55 : 21.9727
HacR_HPE1313A:0_Ch54 : -0.912598
HacR_alignROLL : -0.43348
HacR_alignPITCH : -0.0057925
HacR_alignHPT : 2.45583
HacL_HPM_LVDT:VALr : -6526
HacL_VPM_LVDT:VALr : 852
HacL_HPE1313A:0_Ch58 : -0.17041
HacL_HPE1313A:0_Ch55 : 23.4375
HacL_HPE1313A:0_Ch54 : -0.286621
HacL_alignROLL : 0.0791258
HacL_alignPITCH : -0.0927883
HacL_alignHPT : 3.53469
Right Arm Angle Floor Angle : 40
Right Arm Angle Vernier : -34.5
Right Arm Scattering Angle : 39.9815
Left Arm Angle Floor Angle : 30
Left Arm Angle Vernier : 31.5
Left Arm Scattering Angle : 29.9786
Wien angle :
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 185
Laser power Hall A : 63
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88