Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 10:57:00 on October 1, 2000
Entry number 48884
keyword=Start_Run_1239_Tar=4He-10cm,Type=Elastic,Pmom=0.80078,Emom=0.68391,Ene=826,Angle_e=39.982,Angle_h=29.979
Beginning-of-run EPICS data for Run Number 1239 at Sun Oct 1 10:56:45 EDT 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=16,ps2=1,ps3=16,ps4=40,ps5=1000,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 514.22
Right Arm Q1 momentum : 0.683862
Right Arm Q1 gauss meter : -0.012927
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 294.293
Right Arm Q2 momentum : 0.683818
Right Arm Q2 gauss meter : 0.15496
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 234.226
Right Arm D1 momentum : 0.68391
Right Arm D1 NMR : 0.253791
Right Arm Q3 power supply current : 272.082
Right Arm Q3 momentum : 0.683781
Right Arm Q3 gauss meter : 0.12211
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 602.175
Left Arm Q1 momentum : 0.800412
Left Arm Q1 gauss meter : -0.05096
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 344.839
Left Arm Q2 momentum : 0.800835
Left Arm Q2 gauss meter : 0.18247
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 267.345
Left Arm D1 momentum : 0.800786
Left Arm D1 NMR : 0.296525
Left Arm Q3 power supply current : 318.883
Left Arm Q3 momentum : 0.800976
Left Arm Q3 gauss meter : -0.15885
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 10.002
Current on Unser monitor : 11.9537
Current on Upstream bcm : 10.1003
Current on Downstream bcm : 9.90365
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 10.1245
Beam energy : 825.959
MBSY1c magnet current (amp) : 34.0388
Radiator 5V Linear Supply :
Radiator Encoder :
haBDSPOS : 6.517e+06
haL1_Fan_frequency_R : 65
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 243.17
haSC200_6_Sensor_2_R : 226.02
haSC200_6_Sensor_3_R : -0.13
haSC200_6_Sensor_4_R : 35.65
haHe_Omega_DPG_Sensor_R : 5.649
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.79
haITC502_1_Sensor_3_R : 5.89999
haITC502_4_Sensor_1_R : 6.1
haITC502_4_Sensor_2_R : 151.3
haITC502_4_Sensor_3_R : 99.8
haITC502_5_Sensor_1_R : 5.83
haITC502_5_Sensor_2_R : 5.81
haITC502_5_Sensor_3_R : 197.7
haITC502_6_Sensor_1_R : 5.85
haITC502_6_Sensor_2_R : 5.96
haITC502_6_Sensor_3_R : 26.84
Right Arm Arm Collimator : 0.615039
Left Arm Arm Collimator : 0.616992
HacR_HPM_LVDT:VALr : -4684
HacR_VPM_LVDT:VALr : 66
HacR_HPE1313A:0_Ch58 : -0.549316
HacR_HPE1313A:0_Ch55 : 21.9727
HacR_HPE1313A:0_Ch54 : -0.913086
HacR_alignROLL : -0.432987
HacR_alignPITCH : -0.00534377
HacR_alignHPT : 2.45666
HacL_HPM_LVDT:VALr : -6528
HacL_VPM_LVDT:VALr : 854
HacL_HPE1313A:0_Ch58 : -0.169434
HacL_HPE1313A:0_Ch55 : 23.4375
HacL_HPE1313A:0_Ch54 : -0.286621
HacL_alignROLL : 0.0781721
HacL_alignPITCH : -0.0931515
HacL_alignHPT : 3.53626
Right Arm Angle Floor Angle : 40
Right Arm Angle Vernier : -34.5
Right Arm Scattering Angle : 39.9815
Left Arm Angle Floor Angle : 30
Left Arm Angle Vernier : 31.5
Left Arm Scattering Angle : 29.9786
Wien angle :
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 185
Laser power Hall A : 63
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88