User name adev
Log entry time 11:26:13 on October 1, 2000
Entry number 48888
keyword=End_of_Run_1240
End-of-run EPICS data for Run Number 1240 at Sun Oct 1 11:25:54 EDT 2000
Right Arm D1 momentum : 0.68391
Right Arm arm angle : 39.9815
Left Arm D1 momentum : 0.800786
Left Arm arm angle : 29.9786
Tiefenbach Hall A energy : 825.088
Right Arm arm mispointing (HPT) : 2.46027
Left Arm arm mispointing (HPT) : 3.5349
Right Arm Q1 power supply current : 514.22
Right Arm Q1 momentum : 0.683862
Right Arm Q1 gauss meter : -0.012925
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 294.362
Right Arm Q2 momentum : 0.683978
Right Arm Q2 gauss meter : 0.15489
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 234.227
Right Arm D1 momentum : 0.68391
Right Arm D1 NMR : 0.253791
Right Arm Q3 power supply current : 272.126
Right Arm Q3 momentum : 0.683841
Right Arm Q3 gauss meter : 0.1221
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 602.175
Left Arm Q1 momentum : 0.800412
Left Arm Q1 gauss meter : -0.05099
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 344.586
Left Arm Q2 momentum : 0.800247
Left Arm Q2 gauss meter : 0.18235
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 267.344
Left Arm D1 momentum : 0.800786
Left Arm D1 NMR : 0.296525
Left Arm Q3 power supply current : 318.855
Left Arm Q3 momentum : 0.800903
Left Arm Q3 gauss meter : -0.15888
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 19.7965
Current on Unser monitor : 21.6027
Current on Upstream bcm : 20.0573
Current on Downstream bcm : 19.5357
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 19.9468
MBSY1c Hall A Beam energy : 825.959
MBSY1c magnet current (amp) : 34.0388
MBSY1c Bdl : 206119
MBSY3c Hall C Beam energy : 2392.25
Tiefenbach Hall A energy : 825.088
Tiefenbach Hall C energy : 2383.96
Delta(E)/E width (MV_AI_DXWID) : 4.1305
IPM1C12.XPOS : -0.000231355
IPM1H04A.XPOS : -0.738562
IPM1H04A.YPOS : 0.150224
IPM1H04B.XPOS : 0.0266236
IPM1H04B.YPOS : -0.00706138
Right Arm Arm Collimator : 0.615039
Left Arm Arm Collimator : 0.617041
HacR_HPM_LVDT:VALr : -4685
HacR_VPM_LVDT:VALr : 68
HacR_HPE1313A:0_Ch58 : -0.548828
HacR_HPE1313A:0_Ch55 : 21.9727
HacR_HPE1313A:0_Ch54 : -0.912598
HacR_alignROLL : -0.43348
HacR_alignPITCH : -0.00668997
HacR_alignHPT : 2.45805
HacL_HPM_LVDT:VALr : -6528
HacL_VPM_LVDT:VALr : 857
HacL_HPE1313A:0_Ch58 : -0.169922
HacL_HPE1313A:0_Ch55 : 23.4863
HacL_HPE1313A:0_Ch54 : -0.284668
HacL_alignROLL : 0.0800093
HacL_alignPITCH : -0.0927883
HacL_alignHPT : 3.53426
haBDSPOS : 6.517e+06
haL1_Fan_frequency_R : 63
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haH2_P_Fill_Target_R : 26.49
haH2_P_Exhaust_R : 26.8
haH2_P_Fill_Bottle_R : 26.84
haH2_DP_Fill_Exhaust_R : 0
haD2_P_Fill_Target_R : 0
haD2_P_Exhaust_R : 0
haD2_P_Fill_Bottle_R : 0
haD2_DP_Fill_Exhaust_R : 27.471
haSC200_6_Sensor_1_R : 243.13
haSC200_6_Sensor_2_R : 226.34
haSC200_6_Sensor_3_R : -0.13
haSC200_6_Sensor_4_R : 35.67
haHe_Omega_DPG_Sensor_R : 5.658
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.79
haITC502_1_Sensor_3_R : 5.90999
haITC502_2_Sensor_1_R : 94.98
haITC502_2_Sensor_2_R : 94.98
haITC502_2_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 6.1
haITC502_4_Sensor_2_R : 153.5
haITC502_4_Sensor_3_R : 100.1
haITC502_5_Sensor_1_R : 5.83
haITC502_5_Sensor_2_R : 5.81
haITC502_5_Sensor_3_R : 197.7
haITC502_6_Sensor_1_R : 5.87
haITC502_6_Sensor_2_R : 5.85
haITC502_6_Sensor_3_R : 26.84
Right Arm VDC Top HV :
Right Arm VDC Bottom HV :
Left Arm VDC Top HV :
Left Arm VDC Bottom HV :
Right Arm Arm Collimator : 0.615039
Left Arm Arm Collimator : 0.617041
Wien angle :
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 294
Laser power Hall A : 63