User name adev
Log entry time 12:10:14 on October 1, 2000
Entry number 48896
keyword=End_of_Run_1243
End-of-run EPICS data for Run Number 1243 at Sun Oct 1 12:09:59 EDT 2000
Right Arm D1 momentum : 0.68391
Right Arm arm angle : 39.9815
Left Arm D1 momentum : 0.800785
Left Arm arm angle : 29.9786
Tiefenbach Hall A energy : 825.093
Right Arm arm mispointing (HPT) : 2.46139
Left Arm arm mispointing (HPT) : 3.53646
Right Arm Q1 power supply current : 514.22
Right Arm Q1 momentum : 0.683862
Right Arm Q1 gauss meter : -0.012919
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 294.209
Right Arm Q2 momentum : 0.683622
Right Arm Q2 gauss meter : 0.15493
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 234.226
Right Arm D1 momentum : 0.68391
Right Arm D1 NMR : 0.253791
Right Arm Q3 power supply current : 272.239
Right Arm Q3 momentum : 0.684174
Right Arm Q3 gauss meter : 0.12212
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 602.175
Left Arm Q1 momentum : 0.800412
Left Arm Q1 gauss meter : -0.05097
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 344.697
Left Arm Q2 momentum : 0.800504
Left Arm Q2 gauss meter : 0.18246
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 267.345
Left Arm D1 momentum : 0.800785
Left Arm D1 NMR : 0.296525
Left Arm Q3 power supply current : 318.815
Left Arm Q3 momentum : 0.800803
Left Arm Q3 gauss meter : -0.15886
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 30.4487
Current on Unser monitor : 32.2875
Current on Upstream bcm : 30.8028
Current on Downstream bcm : 30.0945
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 30.6707
MBSY1c Hall A Beam energy : 825.959
MBSY1c magnet current (amp) : 34.0388
MBSY1c Bdl : 206119
MBSY3c Hall C Beam energy : 2392.25
Tiefenbach Hall A energy : 825.093
Tiefenbach Hall C energy : 2383.96
Delta(E)/E width (MV_AI_DXWID) : 4.12414
IPM1C12.XPOS : -0.00647551
IPM1H04A.XPOS : -0.733791
IPM1H04A.YPOS : 0.202861
IPM1H04B.XPOS : 0.0286366
IPM1H04B.YPOS : 0.0547453
Right Arm Arm Collimator : 0.61499
Left Arm Arm Collimator : 0.617041
HacR_HPM_LVDT:VALr : -4686
HacR_VPM_LVDT:VALr : 70
HacR_HPE1313A:0_Ch58 : -0.548828
HacR_HPE1313A:0_Ch55 : 21.9727
HacR_HPE1313A:0_Ch54 : -0.914062
HacR_alignROLL : -0.434409
HacR_alignPITCH : -0.00675616
HacR_alignHPT : 2.4608
HacL_HPM_LVDT:VALr : -6529
HacL_VPM_LVDT:VALr : 857
HacL_HPE1313A:0_Ch58 : -0.169922
HacL_HPE1313A:0_Ch55 : 23.3887
HacL_HPE1313A:0_Ch54 : -0.285645
HacL_alignROLL : 0.0798686
HacL_alignPITCH : -0.0930777
HacL_alignHPT : 3.53433
haBDSPOS : 6.517e+06
haL1_Fan_frequency_R : 64
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haH2_P_Fill_Target_R : 26.53
haH2_P_Exhaust_R : 26.83
haH2_P_Fill_Bottle_R : 26.89
haH2_DP_Fill_Exhaust_R : 0
haD2_P_Fill_Target_R : 0
haD2_P_Exhaust_R : 0
haD2_P_Fill_Bottle_R : 0
haD2_DP_Fill_Exhaust_R : 27.388
haSC200_6_Sensor_1_R : 243.2
haSC200_6_Sensor_2_R : 227.02
haSC200_6_Sensor_3_R : -0.13
haSC200_6_Sensor_4_R : 35.69
haHe_Omega_DPG_Sensor_R : 5.626
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.79
haITC502_1_Sensor_3_R : 5.93999
haITC502_2_Sensor_1_R : 94.98
haITC502_2_Sensor_2_R : 94.98
haITC502_2_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 6.1
haITC502_4_Sensor_2_R : 156.8
haITC502_4_Sensor_3_R : 100.4
haITC502_5_Sensor_1_R : 5.84
haITC502_5_Sensor_2_R : 5.81
haITC502_5_Sensor_3_R : 197.7
haITC502_6_Sensor_1_R : 5.89
haITC502_6_Sensor_2_R : 5.92
haITC502_6_Sensor_3_R : 26.84
Right Arm VDC Top HV :
Right Arm VDC Bottom HV :
Left Arm VDC Top HV :
Left Arm VDC Bottom HV :
Right Arm Arm Collimator : 0.615039
Left Arm Arm Collimator : 0.616992
Wien angle :
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 230
Laser power Hall A : 63