User name adev
Log entry time 12:42:37 on October 1, 2000
Entry number 48901
keyword=Start_Run_1245_Tar=4He-10cm,Type=Elastic,Pmom=0.80078,Emom=0.68391,Ene=826,Angle_e=39.982,Angle_h=29.979
Beginning-of-run EPICS data for Run Number 1245 at Sun Oct 1 12:42:25 EDT 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=70,ps2=20,ps3=70,ps4=500,ps5=1000,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 514.22
Right Arm Q1 momentum : 0.683862
Right Arm Q1 gauss meter : -0.012917
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 294.299
Right Arm Q2 momentum : 0.683833
Right Arm Q2 gauss meter : 0.15499
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 234.225
Right Arm D1 momentum : 0.68391
Right Arm D1 NMR : 0.253791
Right Arm Q3 power supply current : 272.111
Right Arm Q3 momentum : 0.683853
Right Arm Q3 gauss meter : 0.12209
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 602.175
Left Arm Q1 momentum : 0.800412
Left Arm Q1 gauss meter : -0.05096
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 344.954
Left Arm Q2 momentum : 0.8011
Left Arm Q2 gauss meter : 0.18249
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 267.344
Left Arm D1 momentum : 0.800786
Left Arm D1 NMR : 0.296525
Left Arm Q3 power supply current : 318.767
Left Arm Q3 momentum : 0.800684
Left Arm Q3 gauss meter : -0.15885
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 39.941
Current on Unser monitor : 42.0757
Current on Upstream bcm : 40.4307
Current on Downstream bcm : 39.4514
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 40.3993
Beam energy : 825.959
MBSY1c magnet current (amp) : 34.0388
Radiator 5V Linear Supply :
Radiator Encoder :
haBDSPOS : 6.517e+06
haL1_Fan_frequency_R : 67
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 243.15
haSC200_6_Sensor_2_R : 227.6
haSC200_6_Sensor_3_R : -0.15
haSC200_6_Sensor_4_R : 35.65
haHe_Omega_DPG_Sensor_R : 5.765
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.79
haITC502_1_Sensor_3_R : 5.96999
haITC502_4_Sensor_1_R : 6.1
haITC502_4_Sensor_2_R : 159.2
haITC502_4_Sensor_3_R : 100.7
haITC502_5_Sensor_1_R : 5.86
haITC502_5_Sensor_2_R : 5.82
haITC502_5_Sensor_3_R : 197.9
haITC502_6_Sensor_1_R : 5.93
haITC502_6_Sensor_2_R : 5.91
haITC502_6_Sensor_3_R : 26.85
Right Arm Arm Collimator : 0.615039
Left Arm Arm Collimator : 0.617041
HacR_HPM_LVDT:VALr : -4688
HacR_VPM_LVDT:VALr : 73
HacR_HPE1313A:0_Ch58 : -0.548828
HacR_HPE1313A:0_Ch55 : 22.0215
HacR_HPE1313A:0_Ch54 : -0.914062
HacR_alignROLL : -0.435014
HacR_alignPITCH : -0.00662377
HacR_alignHPT : 2.46114
HacL_HPM_LVDT:VALr : -6528
HacL_VPM_LVDT:VALr : 857
HacL_HPE1313A:0_Ch58 : -0.169434
HacL_HPE1313A:0_Ch55 : 23.4863
HacL_HPE1313A:0_Ch54 : -0.283691
HacL_alignROLL : 0.0808927
HacL_alignPITCH : -0.0923517
HacL_alignHPT : 3.53719
Right Arm Angle Floor Angle : 40
Right Arm Angle Vernier : -34.5
Right Arm Scattering Angle : 39.9815
Left Arm Angle Floor Angle : 30
Left Arm Angle Vernier : 31.5
Left Arm Scattering Angle : 29.9786
Wien angle :
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 195
Laser power Hall A : 63
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88