User name adev
Log entry time 13:04:57 on October 1, 2000
Entry number 48903
keyword=Start_Run_1246_Tar=4He-10cm,Type=Elastic,Pmom=0.80078,Emom=0.68391,Ene=826,Angle_e=39.982,Angle_h=29.979
Beginning-of-run EPICS data for Run Number 1246 at Sun Oct 1 13:04:42 EDT 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=70,ps2=20,ps3=70,ps4=520,ps5=1000,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 514.29
Right Arm Q1 momentum : 0.683955
Right Arm Q1 gauss meter : -0.012924
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 294.274
Right Arm Q2 momentum : 0.683775
Right Arm Q2 gauss meter : 0.1549
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 234.225
Right Arm D1 momentum : 0.68391
Right Arm D1 NMR : 0.253791
Right Arm Q3 power supply current : 272.177
Right Arm Q3 momentum : 0.684018
Right Arm Q3 gauss meter : 0.12203
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 602.175
Left Arm Q1 momentum : 0.800412
Left Arm Q1 gauss meter : -0.05099
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 344.964
Left Arm Q2 momentum : 0.801123
Left Arm Q2 gauss meter : 0.18245
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 267.344
Left Arm D1 momentum : 0.800785
Left Arm D1 NMR : 0.296525
Left Arm Q3 power supply current : 318.841
Left Arm Q3 momentum : 0.800869
Left Arm Q3 gauss meter : -0.15888
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 49.8306
Current on Unser monitor : 53.157
Current on Upstream bcm : 50.4122
Current on Downstream bcm : 49.249
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 50.0944
Beam energy : 825.959
MBSY1c magnet current (amp) : 34.0388
Radiator 5V Linear Supply :
Radiator Encoder :
haBDSPOS : 6.517e+06
haL1_Fan_frequency_R : 64.5
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 243.18
haSC200_6_Sensor_2_R : 228.06
haSC200_6_Sensor_3_R : -0.15
haSC200_6_Sensor_4_R : 35.64
haHe_Omega_DPG_Sensor_R : 5.665
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.79
haITC502_1_Sensor_3_R : 5.98999
haITC502_4_Sensor_1_R : 6.2
haITC502_4_Sensor_2_R : 160.7
haITC502_4_Sensor_3_R : 100.8
haITC502_5_Sensor_1_R : 5.86
haITC502_5_Sensor_2_R : 5.81
haITC502_5_Sensor_3_R : 197.8
haITC502_6_Sensor_1_R : 5.95
haITC502_6_Sensor_2_R : 5.93
haITC502_6_Sensor_3_R : 26.86
Right Arm Arm Collimator : 0.615039
Left Arm Arm Collimator : 0.617041
HacR_HPM_LVDT:VALr : -4686
HacR_VPM_LVDT:VALr : 72
HacR_HPE1313A:0_Ch58 : -0.54834
HacR_HPE1313A:0_Ch55 : 21.9238
HacR_HPE1313A:0_Ch54 : -0.914551
HacR_alignROLL : -0.435507
HacR_alignPITCH : -0.00707245
HacR_alignHPT : 2.46031
HacL_HPM_LVDT:VALr : -6530
HacL_VPM_LVDT:VALr : 855
HacL_HPE1313A:0_Ch58 : -0.169922
HacL_HPE1313A:0_Ch55 : 23.4863
HacL_HPE1313A:0_Ch54 : -0.28418
HacL_alignROLL : 0.080451
HacL_alignPITCH : -0.0927883
HacL_alignHPT : 3.53629
Right Arm Angle Floor Angle : 40
Right Arm Angle Vernier : -34.5
Right Arm Scattering Angle : 39.9815
Left Arm Angle Floor Angle : 30
Left Arm Angle Vernier : 31.5
Left Arm Scattering Angle : 29.9786
Wien angle :
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 225
Laser power Hall A : 0
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88