User name adev
Log entry time 13:29:55 on October 1, 2000
Entry number 48905
keyword=Start_Run_1247_Tar=4He-10cm,Type=Elastic,Pmom=0.80078,Emom=0.68391,Ene=826,Angle_e=39.982,Angle_h=29.979
Beginning-of-run EPICS data for Run Number 1247 at Sun Oct 1 13:29:38 EDT 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=80,ps2=30,ps3=80,ps4=550,ps5=1000,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 514.22
Right Arm Q1 momentum : 0.683862
Right Arm Q1 gauss meter : -0.012921
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 294.41
Right Arm Q2 momentum : 0.68409
Right Arm Q2 gauss meter : 0.15498
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 234.226
Right Arm D1 momentum : 0.68391
Right Arm D1 NMR : 0.253791
Right Arm Q3 power supply current : 272.133
Right Arm Q3 momentum : 0.683908
Right Arm Q3 gauss meter : 0.12202
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 602.245
Left Arm Q1 momentum : 0.800505
Left Arm Q1 gauss meter : -0.05097
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 344.69
Left Arm Q2 momentum : 0.800488
Left Arm Q2 gauss meter : 0.18242
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 267.347
Left Arm D1 momentum : 0.800783
Left Arm D1 NMR : 0.296524
Left Arm Q3 power supply current : 318.683
Left Arm Q3 momentum : 0.800472
Left Arm Q3 gauss meter : -0.15884
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 62.0937
Current on Unser monitor : 64.8975
Current on Upstream bcm : 62.8283
Current on Downstream bcm : 61.359
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 62.8976
Beam energy : 825.959
MBSY1c magnet current (amp) : 34.0388
Radiator 5V Linear Supply :
Radiator Encoder :
haBDSPOS : 6.517e+06
haL1_Fan_frequency_R : 66
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 243.2
haSC200_6_Sensor_2_R : 228.94
haSC200_6_Sensor_3_R : -0.15
haSC200_6_Sensor_4_R : 35.64
haHe_Omega_DPG_Sensor_R : 5.719
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.79
haITC502_1_Sensor_3_R : 6.01999
haITC502_4_Sensor_1_R : 6.2
haITC502_4_Sensor_2_R : 162.5
haITC502_4_Sensor_3_R : 101
haITC502_5_Sensor_1_R : 5.87
haITC502_5_Sensor_2_R : 5.81
haITC502_5_Sensor_3_R : 197.7
haITC502_6_Sensor_1_R : 5.98
haITC502_6_Sensor_2_R : 5.98
haITC502_6_Sensor_3_R : 26.85
Right Arm Arm Collimator : 0.61499
Left Arm Arm Collimator : 0.616943
HacR_HPM_LVDT:VALr : -4687
HacR_VPM_LVDT:VALr : 72
HacR_HPE1313A:0_Ch58 : -0.548828
HacR_HPE1313A:0_Ch55 : 21.9238
HacR_HPE1313A:0_Ch54 : -0.914551
HacR_alignROLL : -0.435999
HacR_alignPITCH : -0.00662377
HacR_alignHPT : 2.4617
HacL_HPM_LVDT:VALr : -6531
HacL_VPM_LVDT:VALr : 855
HacL_HPE1313A:0_Ch58 : -0.169922
HacL_HPE1313A:0_Ch55 : 23.4375
HacL_HPE1313A:0_Ch54 : -0.28418
HacL_alignROLL : 0.080451
HacL_alignPITCH : -0.0936615
HacL_alignHPT : 3.53852
Right Arm Angle Floor Angle : 40
Right Arm Angle Vernier : -34.5
Right Arm Scattering Angle : 39.9815
Left Arm Angle Floor Angle : 30
Left Arm Angle Vernier : 31.5
Left Arm Scattering Angle : 29.9786
Wien angle :
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 259
Laser power Hall A : 63
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88