User name adev
Log entry time 13:50:30 on October 1, 2000
Entry number 48907
keyword=End_of_Run_1247
End-of-run EPICS data for Run Number 1247 at Sun Oct 1 13:50:15 EDT 2000
Right Arm D1 momentum : 0.68391
Right Arm arm angle : 39.9815
Left Arm D1 momentum : 0.800785
Left Arm arm angle : 29.9786
Tiefenbach Hall A energy : 825.092
Right Arm arm mispointing (HPT) : 2.46281
Left Arm arm mispointing (HPT) : 3.53611
Right Arm Q1 power supply current : 514.29
Right Arm Q1 momentum : 0.683955
Right Arm Q1 gauss meter : -0.012915
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 294.421
Right Arm Q2 momentum : 0.684115
Right Arm Q2 gauss meter : 0.15499
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 234.226
Right Arm D1 momentum : 0.68391
Right Arm D1 NMR : 0.253791
Right Arm Q3 power supply current : 272.21
Right Arm Q3 momentum : 0.684101
Right Arm Q3 gauss meter : 0.12205
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 602.245
Left Arm Q1 momentum : 0.800505
Left Arm Q1 gauss meter : -0.05097
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 344.935
Left Arm Q2 momentum : 0.801056
Left Arm Q2 gauss meter : 0.18251
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 267.345
Left Arm D1 momentum : 0.800786
Left Arm D1 NMR : 0.296525
Left Arm Q3 power supply current : 318.687
Left Arm Q3 momentum : 0.800481
Left Arm Q3 gauss meter : -0.15888
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 62.4209
Current on Unser monitor : 63.8912
Current on Upstream bcm : 63.1365
Current on Downstream bcm : 61.7054
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 63.1334
MBSY1c Hall A Beam energy : 825.959
MBSY1c magnet current (amp) : 34.0388
MBSY1c Bdl : 206119
MBSY3c Hall C Beam energy : 2392.25
Tiefenbach Hall A energy : 825.092
Tiefenbach Hall C energy : 2383.96
Delta(E)/E width (MV_AI_DXWID) : 4.32945
IPM1C12.XPOS : -0.00741816
IPM1H04A.XPOS : -0.722032
IPM1H04A.YPOS : 0.243466
IPM1H04B.XPOS : 0.0547332
IPM1H04B.YPOS : 0.102002
Right Arm Arm Collimator : 0.61499
Left Arm Arm Collimator : 0.617041
HacR_HPM_LVDT:VALr : -4688
HacR_VPM_LVDT:VALr : 73
HacR_HPE1313A:0_Ch58 : -0.54834
HacR_HPE1313A:0_Ch55 : 21.9238
HacR_HPE1313A:0_Ch54 : -0.914551
HacR_alignROLL : -0.435507
HacR_alignPITCH : -0.00707245
HacR_alignHPT : 2.46364
HacL_HPM_LVDT:VALr : -6528
HacL_VPM_LVDT:VALr : 856
HacL_HPE1313A:0_Ch58 : -0.169434
HacL_HPE1313A:0_Ch55 : 23.3887
HacL_HPE1313A:0_Ch54 : -0.283691
HacL_alignROLL : 0.080752
HacL_alignPITCH : -0.0930777
HacL_alignHPT : 3.53503
haBDSPOS : 6.517e+06
haL1_Fan_frequency_R : 64.5
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haH2_P_Fill_Target_R : 26.55
haH2_P_Exhaust_R : 26.87
haH2_P_Fill_Bottle_R : 26.93
haH2_DP_Fill_Exhaust_R : 0
haD2_P_Fill_Target_R : 0
haD2_P_Exhaust_R : 0
haD2_P_Fill_Bottle_R : 0
haD2_DP_Fill_Exhaust_R : 27.435
haSC200_6_Sensor_1_R : 243.22
haSC200_6_Sensor_2_R : 228.91
haSC200_6_Sensor_3_R : -0.13
haSC200_6_Sensor_4_R : 35.65
haHe_Omega_DPG_Sensor_R : 5
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.79
haITC502_1_Sensor_3_R : 6.01999
haITC502_2_Sensor_1_R : 94.98
haITC502_2_Sensor_2_R : 94.98
haITC502_2_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 6.2
haITC502_4_Sensor_2_R : 163.8
haITC502_4_Sensor_3_R : 101.1
haITC502_5_Sensor_1_R : 5.87
haITC502_5_Sensor_2_R : 5.81
haITC502_5_Sensor_3_R : 197.7
haITC502_6_Sensor_1_R : 5.98
haITC502_6_Sensor_2_R : 5.96
haITC502_6_Sensor_3_R : 26.86
Right Arm VDC Top HV :
Right Arm VDC Bottom HV :
Left Arm VDC Top HV :
Left Arm VDC Bottom HV :
Right Arm Arm Collimator : 0.61499
Left Arm Arm Collimator : 0.616992
Wien angle :
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 259
Laser power Hall A : 63