User name adev
Log entry time 14:18:40 on October 1, 2000
Entry number 48909
keyword=End_of_Run_1248
End-of-run EPICS data for Run Number 1248 at Sun Oct 1 14:18:25 EDT 2000
Right Arm D1 momentum : 0.68391
Right Arm arm angle : 39.9815
Left Arm D1 momentum : 0.800786
Left Arm arm angle : 29.9786
Tiefenbach Hall A energy : 825.091
Right Arm arm mispointing (HPT) : 2.46424
Left Arm arm mispointing (HPT) : 3.53701
Right Arm Q1 power supply current : 514.22
Right Arm Q1 momentum : 0.683862
Right Arm Q1 gauss meter : -0.012922
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 294.304
Right Arm Q2 momentum : 0.683845
Right Arm Q2 gauss meter : 0.155
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 234.225
Right Arm D1 momentum : 0.68391
Right Arm D1 NMR : 0.253791
Right Arm Q3 power supply current : 272.108
Right Arm Q3 momentum : 0.683844
Right Arm Q3 gauss meter : 0.12203
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 602.245
Left Arm Q1 momentum : 0.800505
Left Arm Q1 gauss meter : -0.05096
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 344.704
Left Arm Q2 momentum : 0.80052
Left Arm Q2 gauss meter : 0.18238
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 267.345
Left Arm D1 momentum : 0.800786
Left Arm D1 NMR : 0.296525
Left Arm Q3 power supply current : 318.902
Left Arm Q3 momentum : 0.801022
Left Arm Q3 gauss meter : -0.15887
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 69.6681
Current on Unser monitor : 71.7937
Current on Upstream bcm : 70.3733
Current on Downstream bcm : 68.9629
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 70.3176
MBSY1c Hall A Beam energy : 825.959
MBSY1c magnet current (amp) : 34.0388
MBSY1c Bdl : 206119
MBSY3c Hall C Beam energy : 2392.25
Tiefenbach Hall A energy : 825.091
Tiefenbach Hall C energy : 2383.96
Delta(E)/E width (MV_AI_DXWID) : 4.2988
IPM1C12.XPOS : 0.00439155
IPM1H04A.XPOS : -0.722292
IPM1H04A.YPOS : 0.244167
IPM1H04B.XPOS : 0.0575728
IPM1H04B.YPOS : 0.100705
Right Arm Arm Collimator : 0.615039
Left Arm Arm Collimator : 0.61709
HacR_HPM_LVDT:VALr : -4690
HacR_VPM_LVDT:VALr : 72
HacR_HPE1313A:0_Ch58 : -0.547852
HacR_HPE1313A:0_Ch55 : 21.875
HacR_HPE1313A:0_Ch54 : -0.915039
HacR_alignROLL : -0.436055
HacR_alignPITCH : -0.00745496
HacR_alignHPT : 2.46507
HacL_HPM_LVDT:VALr : -6529
HacL_VPM_LVDT:VALr : 855
HacL_HPE1313A:0_Ch58 : -0.168457
HacL_HPE1313A:0_Ch55 : 23.4375
HacL_HPE1313A:0_Ch54 : -0.283203
HacL_alignROLL : 0.0812641
HacL_alignPITCH : -0.0940246
HacL_alignHPT : 3.5359
haBDSPOS : 6.517e+06
haL1_Fan_frequency_R : 65.5
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haH2_P_Fill_Target_R : 26.54
haH2_P_Exhaust_R : 26.89
haH2_P_Fill_Bottle_R : 26.93
haH2_DP_Fill_Exhaust_R : 0
haD2_P_Fill_Target_R : 0
haD2_P_Exhaust_R : 0
haD2_P_Fill_Bottle_R : 0
haD2_DP_Fill_Exhaust_R : 27.435
haSC200_6_Sensor_1_R : 243.2
haSC200_6_Sensor_2_R : 229.24
haSC200_6_Sensor_3_R : -0.15
haSC200_6_Sensor_4_R : 35.65
haHe_Omega_DPG_Sensor_R : 5.686
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.79
haITC502_1_Sensor_3_R : 6.03999
haITC502_2_Sensor_1_R : 94.98
haITC502_2_Sensor_2_R : 94.98
haITC502_2_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 6.2
haITC502_4_Sensor_2_R : 165.7
haITC502_4_Sensor_3_R : 101.2
haITC502_5_Sensor_1_R : 5.88
haITC502_5_Sensor_2_R : 5.81
haITC502_5_Sensor_3_R : 197.7
haITC502_6_Sensor_1_R : 6
haITC502_6_Sensor_2_R : 5.98
haITC502_6_Sensor_3_R : 26.85
Right Arm VDC Top HV :
Right Arm VDC Bottom HV :
Left Arm VDC Top HV :
Left Arm VDC Bottom HV :
Right Arm Arm Collimator : 0.615039
Left Arm Arm Collimator : 0.617041
Wien angle :
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 284
Laser power Hall A : 63