User name adev
Log entry time 15:09:49 on October 1, 2000
Entry number 48915
keyword=Start_Run_1251_Tar=4He-10cm,Type=Elastic,Pmom=0.80078,Emom=0.68391,Ene=826,Angle_e=39.982,Angle_h=29.979
Beginning-of-run EPICS data for Run Number 1251 at Sun Oct 1 15:09:32 EDT 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=120,ps2=60,ps3=120,ps4=800,ps5=1000,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 514.22
Right Arm Q1 momentum : 0.683862
Right Arm Q1 gauss meter : -0.012916
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 294.329
Right Arm Q2 momentum : 0.683902
Right Arm Q2 gauss meter : 0.15491
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 234.226
Right Arm D1 momentum : 0.68391
Right Arm D1 NMR : 0.253791
Right Arm Q3 power supply current : 272.081
Right Arm Q3 momentum : 0.683778
Right Arm Q3 gauss meter : 0.12206
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 602.28
Left Arm Q1 momentum : 0.800551
Left Arm Q1 gauss meter : -0.05098
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 345.084
Left Arm Q2 momentum : 0.801403
Left Arm Q2 gauss meter : 0.18248
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 267.346
Left Arm D1 momentum : 0.800785
Left Arm D1 NMR : 0.296525
Left Arm Q3 power supply current : 318.892
Left Arm Q3 momentum : 0.800998
Left Arm Q3 gauss meter : -0.15887
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 98.9955
Current on Unser monitor : 101.124
Current on Upstream bcm : 100.28
Current on Downstream bcm : 97.7113
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 99.5839
Beam energy : 825.959
MBSY1c magnet current (amp) : 34.0388
Radiator 5V Linear Supply :
Radiator Encoder :
haBDSPOS : 6.517e+06
haL1_Fan_frequency_R : 68
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 243.17
haSC200_6_Sensor_2_R : 230.55
haSC200_6_Sensor_3_R : -0.17
haSC200_6_Sensor_4_R : 35.69
haHe_Omega_DPG_Sensor_R : 5.689
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.79
haITC502_1_Sensor_3_R : 6.09999
haITC502_4_Sensor_1_R : 6.3
haITC502_4_Sensor_2_R : 169
haITC502_4_Sensor_3_R : 101.4
haITC502_5_Sensor_1_R : 5.9
haITC502_5_Sensor_2_R : 5.81
haITC502_5_Sensor_3_R : 197.6
haITC502_6_Sensor_1_R : 6.07
haITC502_6_Sensor_2_R : 6.05
haITC502_6_Sensor_3_R : 26.85
Right Arm Arm Collimator : 0.615039
Left Arm Arm Collimator : 0.617041
HacR_HPM_LVDT:VALr : -4690
HacR_VPM_LVDT:VALr : 69
HacR_HPE1313A:0_Ch58 : -0.547852
HacR_HPE1313A:0_Ch55 : 21.875
HacR_HPE1313A:0_Ch54 : -0.915527
HacR_alignROLL : -0.438026
HacR_alignPITCH : -0.00745496
HacR_alignHPT : 2.46619
HacL_HPM_LVDT:VALr : -6531
HacL_VPM_LVDT:VALr : 850
HacL_HPE1313A:0_Ch58 : -0.169922
HacL_HPE1313A:0_Ch55 : 23.4375
HacL_HPE1313A:0_Ch54 : -0.283203
HacL_alignROLL : 0.0812641
HacL_alignPITCH : -0.0927149
HacL_alignHPT : 3.53813
Right Arm Angle Floor Angle : 40
Right Arm Angle Vernier : -34.5
Right Arm Scattering Angle : 39.9814
Left Arm Angle Floor Angle : 30
Left Arm Angle Vernier : 31.5
Left Arm Scattering Angle : 29.9786
Wien angle :
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 491
Laser power Hall A : 63
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88