User name adev
Log entry time 15:23:18 on October 1, 2000
Entry number 48916
keyword=End_of_Run_1251
End-of-run EPICS data for Run Number 1251 at Sun Oct 1 15:22:54 EDT 2000
Right Arm D1 momentum : 0.683909
Right Arm arm angle : 39.9814
Left Arm D1 momentum : 0.800787
Left Arm arm angle : 29.9786
Tiefenbach Hall A energy : 825.095
Right Arm arm mispointing (HPT) : 2.46671
Left Arm arm mispointing (HPT) : 3.54037
Right Arm Q1 power supply current : 514.22
Right Arm Q1 momentum : 0.683862
Right Arm Q1 gauss meter : -0.012922
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 294.497
Right Arm Q2 momentum : 0.684293
Right Arm Q2 gauss meter : 0.15498
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 234.226
Right Arm D1 momentum : 0.683909
Right Arm D1 NMR : 0.253791
Right Arm Q3 power supply current : 272.151
Right Arm Q3 momentum : 0.683953
Right Arm Q3 gauss meter : 0.12212
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 602.245
Left Arm Q1 momentum : 0.800505
Left Arm Q1 gauss meter : -0.05095
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 344.789
Left Arm Q2 momentum : 0.800719
Left Arm Q2 gauss meter : 0.18238
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 267.344
Left Arm D1 momentum : 0.800787
Left Arm D1 NMR : 0.296526
Left Arm Q3 power supply current : 318.813
Left Arm Q3 momentum : 0.800798
Left Arm Q3 gauss meter : -0.15886
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 97.8126
Current on Unser monitor : 101.048
Current on Upstream bcm : 99.4497
Current on Downstream bcm : 96.1755
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 99.1994
MBSY1c Hall A Beam energy : 825.959
MBSY1c magnet current (amp) : 34.0388
MBSY1c Bdl : 206119
MBSY3c Hall C Beam energy : 2392.25
Tiefenbach Hall A energy : 825.095
Tiefenbach Hall C energy : 2383.96
Delta(E)/E width (MV_AI_DXWID) : 4.30245
IPM1C12.XPOS : 0.0180407
IPM1H04A.XPOS : -0.699875
IPM1H04A.YPOS : 0.238049
IPM1H04B.XPOS : 0.0566649
IPM1H04B.YPOS : 0.0557997
Right Arm Arm Collimator : 0.61499
Left Arm Arm Collimator : 0.616992
HacR_HPM_LVDT:VALr : -4691
HacR_VPM_LVDT:VALr : 68
HacR_HPE1313A:0_Ch58 : -0.549316
HacR_HPE1313A:0_Ch55 : 21.9727
HacR_HPE1313A:0_Ch54 : -0.915039
HacR_alignROLL : -0.435944
HacR_alignPITCH : -0.00624123
HacR_alignHPT : 2.46611
HacL_HPM_LVDT:VALr : -6531
HacL_VPM_LVDT:VALr : 852
HacL_HPE1313A:0_Ch58 : -0.169922
HacL_HPE1313A:0_Ch55 : 23.3887
HacL_HPE1313A:0_Ch54 : -0.283203
HacL_alignROLL : 0.0811937
HacL_alignPITCH : -0.0926411
HacL_alignHPT : 3.53817
haBDSPOS : 6.517e+06
haL1_Fan_frequency_R : 66
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haH2_P_Fill_Target_R : 26.54
haH2_P_Exhaust_R : 26.87
haH2_P_Fill_Bottle_R : 26.98
haH2_DP_Fill_Exhaust_R : 0
haD2_P_Fill_Target_R : 0
haD2_P_Exhaust_R : 0
haD2_P_Fill_Bottle_R : 0
haD2_DP_Fill_Exhaust_R : 27.435
haSC200_6_Sensor_1_R : 243.13
haSC200_6_Sensor_2_R : 230.25
haSC200_6_Sensor_3_R : -0.17
haSC200_6_Sensor_4_R : 35.67
haHe_Omega_DPG_Sensor_R : 5.62
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.79
haITC502_1_Sensor_3_R : 6.09999
haITC502_2_Sensor_1_R : 94.98
haITC502_2_Sensor_2_R : 94.98
haITC502_2_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 6.3
haITC502_4_Sensor_2_R : 169.8
haITC502_4_Sensor_3_R : 101.4
haITC502_5_Sensor_1_R : 5.9
haITC502_5_Sensor_2_R : 5.8
haITC502_5_Sensor_3_R : 197.6
haITC502_6_Sensor_1_R : 6.06
haITC502_6_Sensor_2_R : 6.04
haITC502_6_Sensor_3_R : 26.85
Right Arm VDC Top HV :
Right Arm VDC Bottom HV :
Left Arm VDC Top HV :
Left Arm VDC Bottom HV :
Right Arm Arm Collimator : 0.61499
Left Arm Arm Collimator : 0.616992
Wien angle :
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 491
Laser power Hall A : 63