User name adev
Log entry time 15:48:13 on October 1, 2000
Entry number 48917
keyword=Start_Run_1255_Tar=4He-10cm,Type=Elastic,Pmom=0.80078,Emom=0.68391,Ene=826,Angle_e=39.982,Angle_h=29.979
Beginning-of-run EPICS data for Run Number 1255 at Sun Oct 1 15:47:53 EDT 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=120,ps2=60,ps3=120,ps4=800,ps5=1000,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 514.22
Right Arm Q1 momentum : 0.683862
Right Arm Q1 gauss meter : -0.012925
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 294.223
Right Arm Q2 momentum : 0.683655
Right Arm Q2 gauss meter : 0.15489
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 234.227
Right Arm D1 momentum : 0.68391
Right Arm D1 NMR : 0.253791
Right Arm Q3 power supply current : 272.1
Right Arm Q3 momentum : 0.683826
Right Arm Q3 gauss meter : 0.12212
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 602.175
Left Arm Q1 momentum : 0.800412
Left Arm Q1 gauss meter : -0.05097
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 345.027
Left Arm Q2 momentum : 0.80127
Left Arm Q2 gauss meter : 0.1824
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 267.345
Left Arm D1 momentum : 0.800784
Left Arm D1 NMR : 0.296525
Left Arm Q3 power supply current : 318.927
Left Arm Q3 momentum : 0.801085
Left Arm Q3 gauss meter : -0.15888
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 91.9468
Current on Unser monitor : 95.2422
Current on Upstream bcm : 93.2492
Current on Downstream bcm : 90.8115
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 93.2468
Beam energy : 825.959
MBSY1c magnet current (amp) : 34.0388
Radiator 5V Linear Supply :
Radiator Encoder :
haBDSPOS : 6.517e+06
haL1_Fan_frequency_R : 67
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 243.1
haSC200_6_Sensor_2_R : 230.35
haSC200_6_Sensor_3_R : -0.22
haSC200_6_Sensor_4_R : 35.65
haHe_Omega_DPG_Sensor_R : 5.652
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.79
haITC502_1_Sensor_3_R : 6.08999
haITC502_4_Sensor_1_R : 6.3
haITC502_4_Sensor_2_R : 171.3
haITC502_4_Sensor_3_R : 101.5
haITC502_5_Sensor_1_R : 5.9
haITC502_5_Sensor_2_R : 5.81
haITC502_5_Sensor_3_R : 197.5
haITC502_6_Sensor_1_R : 6.06
haITC502_6_Sensor_2_R : 6.04
haITC502_6_Sensor_3_R : 26.86
Right Arm Arm Collimator : 0.615039
Left Arm Arm Collimator : 0.617041
HacR_HPM_LVDT:VALr : -4692
HacR_VPM_LVDT:VALr : 70
HacR_HPE1313A:0_Ch58 : -0.54834
HacR_HPE1313A:0_Ch55 : 21.875
HacR_HPE1313A:0_Ch54 : -0.916992
HacR_alignROLL : -0.438026
HacR_alignPITCH : -0.00790367
HacR_alignHPT : 2.46893
HacL_HPM_LVDT:VALr : -6533
HacL_VPM_LVDT:VALr : 853
HacL_HPE1313A:0_Ch58 : -0.169922
HacL_HPE1313A:0_Ch55 : 23.3887
HacL_HPE1313A:0_Ch54 : -0.282715
HacL_alignROLL : 0.0816354
HacL_alignPITCH : -0.0926411
HacL_alignHPT : 3.53907
Right Arm Angle Floor Angle : 40
Right Arm Angle Vernier : -34.5
Right Arm Scattering Angle : 39.9814
Left Arm Angle Floor Angle : 30
Left Arm Angle Vernier : 31.5
Left Arm Scattering Angle : 29.9786
Wien angle :
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 360
Laser power Hall A : 63
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88