    New Crew on shift: Bob Michaels, Mark Jones, Eric Voutier
    ***************

    -# The raster size has been checked using SPOT++ and HARP

    scan 1003 ......... 2 x 2 (raster tuneon screen) .......... about 2 x 3 real mm
    scan 1004 ......... 4 x 2.7 ............................................ about 4 x 4 real mm

    - 9:00 Start target boiling test

    run# 1232 ..... I = 1.00 uA ....... 09:10 / 09:27 ..... good run
    run# 1233 ..... I = 2.10 uA ....... 09:35 / 09:38 ..... good run / higher dead time
    run# 1234 ..... I = 2.10 uA ....... 09:39 / 09:56 ..... good run
    run# 1235 ..... I = 3.10 uA ....... 10:00 / 10:20 ..... good run
    run# 1236 ..... I = 4.50 uA ....... 10:26 / 10:42 ..... good run
    run# 1237 ..... junk
    run# 1238 ..... I = 9.90 uA ....... 10:50 / 10:55 ..... good run / higher deat time
    run# 1239 ..... I = 10.0 uA ....... 10:56 / 11:09 ..... good run
    run# 1240 ..... I = 19.8 uA ....... 11:21 / 11:25 ..... good run / higher dead time
    run# 1241 ..... I = 20.3 uA ....... 11:26 / 11:30 ..... good run / higher dead time
    run# 1242 ..... I = 20.4 uA ....... 11:31 / 11:44 ..... good run / argon alarm low pres.
    run# 1243 ..... I = 30.1 uA ....... 11:55 / 12:10 ..... good run

    - 12:10 Giving the beam to MCC for beam dump checks

    - 12:38 Back on boiling test

    run# 1244 ..... I = 40.2 uA ....... 12:38 / 12:40 ..... good run but wrong ps1
    run# 1245 ..... I = 40.0 uA ....... 12:41 / 13:01 ..... good run
    run# 1246 ..... I = 50.0 uA ....... 13:04 / 13:23 ..... good run / beam breaks
    run# 1247 ..... I = 62.3 uA ....... 13:29 / 13:50 ..... good run
    run# 1248 ..... I = 70.0 uA ....... 14:01 / 14:18 ..... good run
    run# 1249 ..... I = 80.0 uA ....... 14:27 / 14:41 ..... good run
    run# 1250 ..... I = 90.0 uA ....... 14:48 / 15:01 ..... good run
    run# 1251 ..... I = 100. uA ....... 15:09 / 15:22 ..... good run

    - 15:25 Work at the injector level that will forbid high currents for this moment

    - 15:29 Bob is doing checks of the DAQ

    - 15:50 Moving to the carbon target