User name adev
Log entry time 16:18:51 on October 1, 2000
Entry number 48922
keyword=Start_Run_1257_Tar=carbon,Type=Elastic,Pmom=0.80078,Emom=0.68391,Ene=826,Angle_e=39.982,Angle_h=29.979
Beginning-of-run EPICS data for Run Number 1257 at Sun Oct 1 16:18:39 EDT 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=120,ps2=60,ps3=120,ps4=800,ps5=1000,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 514.29
Right Arm Q1 momentum : 0.683723
Right Arm Q1 gauss meter : -0.012924
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 294.398
Right Arm Q2 momentum : 0.684062
Right Arm Q2 gauss meter : 0.15499
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 234.233
Right Arm D1 momentum : 0.683912
Right Arm D1 NMR : 0.253792
Right Arm Q3 power supply current : 272.157
Right Arm Q3 momentum : 0.683968
Right Arm Q3 gauss meter : 0.12212
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 602.245
Left Arm Q1 momentum : 0.800505
Left Arm Q1 gauss meter : -0.05094
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 344.733
Left Arm Q2 momentum : 0.800589
Left Arm Q2 gauss meter : 0.18247
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 267.346
Left Arm D1 momentum : 0.800787
Left Arm D1 NMR : 0.296526
Left Arm Q3 power supply current : 318.85
Left Arm Q3 momentum : 0.800891
Left Arm Q3 gauss meter : -0.15888
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 78.4191
Current on Unser monitor : 81.7509
Current on Upstream bcm : 79.4796
Current on Downstream bcm : 77.3585
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 79.0804
Beam energy : 825.959
MBSY1c magnet current (amp) : 34.0388
Radiator 5V Linear Supply :
Radiator Encoder :
haBDSPOS : 732012
haL1_Fan_frequency_R : 66
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 243.12
haSC200_6_Sensor_2_R : 225.37
haSC200_6_Sensor_3_R : -0.2
haSC200_6_Sensor_4_R : 35.67
haHe_Omega_DPG_Sensor_R : 5.758
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.79
haITC502_1_Sensor_3_R : 5.86999
haITC502_4_Sensor_1_R : 6
haITC502_4_Sensor_2_R : 173.1
haITC502_4_Sensor_3_R : 101.6
haITC502_5_Sensor_1_R : 5.84
haITC502_5_Sensor_2_R : 5.81
haITC502_5_Sensor_3_R : 212.7
haITC502_6_Sensor_1_R : 5.84
haITC502_6_Sensor_2_R : 5.85
haITC502_6_Sensor_3_R : 27.54
Right Arm Arm Collimator : 0.61499
Left Arm Arm Collimator : 0.61709
HacR_HPM_LVDT:VALr : -4707
HacR_VPM_LVDT:VALr : 78
HacR_HPE1313A:0_Ch58 : -0.547363
HacR_HPE1313A:0_Ch55 : 21.9238
HacR_HPE1313A:0_Ch54 : -0.916992
HacR_alignROLL : -0.437971
HacR_alignPITCH : -0.00796992
HacR_alignHPT : 2.48503
HacL_HPM_LVDT:VALr : -6526
HacL_VPM_LVDT:VALr : 871
HacL_HPE1313A:0_Ch58 : -0.169922
HacL_HPE1313A:0_Ch55 : 23.4863
HacL_HPE1313A:0_Ch54 : -0.281738
HacL_alignROLL : 0.0813344
HacL_alignPITCH : -0.0923517
HacL_alignHPT : 3.53139
Right Arm Angle Floor Angle : 40
Right Arm Angle Vernier : -34.5
Right Arm Scattering Angle : 39.9813
Left Arm Angle Floor Angle : 30
Left Arm Angle Vernier : 31.5
Left Arm Scattering Angle : 29.9786
Wien angle :
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 299
Laser power Hall A : 63
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88