    User name adev

    Log entry time 16:52:55 on October 1, 2000

    Entry number 48928

    keyword=Start_Run_1260_Tar=carbon,Type=Elastic,Pmom=0.80078,Emom=0.68391,Ene=826,Angle_e=39.982,Angle_h=29.979
    Beginning-of-run EPICS data for Run Number 1260 at Sun Oct  1 16:52:42 EDT 2000
    ; (Integer!) prescale factors for runs.
    ; This file is read at start of every run.
    ; Do NOT put spaces in string, NOR add 2nd string
    ; The default factor is essentially infinite. 
    ; ps8 = 65535 turns off the 1 kHz pulser on T8.
    ; Keep enough T2 and T4 to measure efficiency
    ;
    ps1=12,ps2=6,ps3=12,ps4=80,ps5=1000,ps6=65535,ps8=65535
    
    Right Arm Q1 power supply current        : 514.115
    Right Arm Q1 momentum                    : 0.683723
    Right Arm Q1 gauss meter                 : -0.012923
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 294.406
    Right Arm Q2 momentum                    : 0.684081
    Right Arm Q2 gauss meter                 : 0.15498
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 234.226
    Right Arm D1 momentum                    : 0.68391
    Right Arm D1 NMR                         : 0.253791
    Right Arm Q3 power supply current        : 272.124
    Right Arm Q3 momentum                    : 0.683886
    Right Arm Q3 gauss meter                 : 0.12211
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 602.14
    Left Arm Q1 momentum                      : 0.800365
    Left Arm Q1 gauss meter                   : -0.05096
    Left Arm Q1 power supply polarity         : 0
    Left Arm Q2 power supply current          : 344.739
    Left Arm Q2 momentum                      : 0.800274
    Left Arm Q2 gauss meter                   : 0.18238
    Left Arm Q2 power supply polarity         : 1
    Left Arm D1 power supply current          : 267.344
    Left Arm D1 momentum                      : 0.800787
    Left Arm D1 NMR                           : 0.296526
    Left Arm Q3 power supply current          : 318.922
    Left Arm Q3 momentum                      : 0.801073
    Left Arm Q3 gauss meter                   : -0.15886
    Left Arm Q3 power supply polarity         : 1
    Average current of the two cavities     : 78.2059
    Current on Unser monitor                : 80.7653
    Current on Upstream bcm                 : 79.1697
    Current on Downstream bcm               : 77.2421
    Upstream Cavity Coefficient             : 77
    Downstream Cavity Coefficient           : 77
     Current on IBC0L02 (source)            : 78.7878
    Beam energy                             : 825.959
    MBSY1c magnet current (amp)             : 34.0388
     Radiator 5V Linear Supply              : 
     Radiator Encoder                       : 
    haBDSPOS                                 : 732012
    haL1_Fan_frequency_R                     : 67
    haL2_Fan_frequency_R                     : 0
    haL3_Fan_frequency_R                     : 0
    haSC200_6_Sensor_1_R                     : 243.12
    haSC200_6_Sensor_2_R                     : 223.07
    haSC200_6_Sensor_3_R                     : -0.2
    haSC200_6_Sensor_4_R                     : 35.64
    haHe_Omega_DPG_Sensor_R                  : 5.663
    haITC502_1_Sensor_1_R                    : 5.8
    haITC502_1_Sensor_2_R                    : 5.79
    haITC502_1_Sensor_3_R                    : 5.87999
    haITC502_4_Sensor_1_R                    : 6
    haITC502_4_Sensor_2_R                    : 174
    haITC502_4_Sensor_3_R                    : 99.8
    haITC502_5_Sensor_1_R                    : 5.84
    haITC502_5_Sensor_2_R                    : 5.81
    haITC502_5_Sensor_3_R                    : 230.9
    haITC502_6_Sensor_1_R                    : 5.83
    haITC502_6_Sensor_2_R                    : 5.82
    haITC502_6_Sensor_3_R                    : 27.91
    Right Arm Arm Collimator                 : 0.61499
    Left Arm Arm Collimator                   : 0.616943
     HacR_HPM_LVDT:VALr                     : -4710
     HacR_VPM_LVDT:VALr                     : 83
     HacR_HPE1313A:0_Ch58                   : -0.547852
     HacR_HPE1313A:0_Ch55                   : 21.9238
     HacR_HPE1313A:0_Ch54                   : -0.916992
     HacR_alignROLL                         : -0.437971
     HacR_alignPITCH                        : -0.00752118
     HacR_alignHPT                          : 2.48947
     HacL_HPM_LVDT:VALr                     : -6527
     HacL_VPM_LVDT:VALr                     : 877
     HacL_HPE1313A:0_Ch58                   : -0.169434
     HacL_HPE1313A:0_Ch55                   : 23.3887
     HacL_HPE1313A:0_Ch54                   : -0.282715
     HacL_alignROLL                         : 0.0816354
     HacL_alignPITCH                        : -0.0930777
     HacL_alignHPT                          : 3.53572
    Right Arm Angle Floor Angle               : 40
    Right Arm Angle Vernier                   : -34.5
    Right Arm Scattering Angle                : 39.9813
    Left Arm Angle Floor Angle                 : 30
    Left Arm Angle Vernier                     : 31.5
    Left Arm Scattering Angle                  : 29.9786
    Wien angle                               : 
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : 1651.6
    Wien field                               : 48.828
    Laser attenuation Hall A                 : 299
    Laser power  Hall A                      : 63
    Survey X offset bpmA                      : -0.32
    Survey Y offset bpmA                      : -0.35
    Survey X offset bpmB                      : -0.05
    Survey Y offset bpmB                      : -0.88