User name adev
Log entry time 17:34:01 on October 1, 2000
Entry number 48929
keyword=Start_Run_1261_Tar=carbon,Type=Elastic,Pmom=0.80078,Emom=0.68391,Ene=826,Angle_e=39.982,Angle_h=29.979
Beginning-of-run EPICS data for Run Number 1261 at Sun Oct 1 17:33:50 EDT 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=12,ps2=6,ps3=12,ps4=80,ps5=1000,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 514.22
Right Arm Q1 momentum : 0.683862
Right Arm Q1 gauss meter : -0.012926
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 294.164
Right Arm Q2 momentum : 0.683518
Right Arm Q2 gauss meter : 0.15495
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 234.224
Right Arm D1 momentum : 0.68391
Right Arm D1 NMR : 0.253791
Right Arm Q3 power supply current : 272.267
Right Arm Q3 momentum : 0.684245
Right Arm Q3 gauss meter : 0.12208
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 602.175
Left Arm Q1 momentum : 0.800412
Left Arm Q1 gauss meter : -0.05095
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 344.842
Left Arm Q2 momentum : 0.800842
Left Arm Q2 gauss meter : 0.18248
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 267.344
Left Arm D1 momentum : 0.800786
Left Arm D1 NMR : 0.296525
Left Arm Q3 power supply current : 318.832
Left Arm Q3 momentum : 0.800847
Left Arm Q3 gauss meter : -0.15888
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 77.8544
Current on Unser monitor : 81.5902
Current on Upstream bcm : 78.6716
Current on Downstream bcm : 77.0372
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 78.6383
Beam energy : 825.959
MBSY1c magnet current (amp) : 34.0388
Radiator 5V Linear Supply :
Radiator Encoder :
haBDSPOS : 732012
haL1_Fan_frequency_R : 65
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 243.08
haSC200_6_Sensor_2_R : 223.3
haSC200_6_Sensor_3_R : -0.2
haSC200_6_Sensor_4_R : 35.62
haHe_Omega_DPG_Sensor_R : 5.712
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.79
haITC502_1_Sensor_3_R : 5.87999
haITC502_4_Sensor_1_R : 6
haITC502_4_Sensor_2_R : 175.2
haITC502_4_Sensor_3_R : 91.3
haITC502_5_Sensor_1_R : 5.84
haITC502_5_Sensor_2_R : 5.81
haITC502_5_Sensor_3_R : 224.4
haITC502_6_Sensor_1_R : 5.84
haITC502_6_Sensor_2_R : 5.81
haITC502_6_Sensor_3_R : 27.83
Right Arm Arm Collimator : 0.615039
Left Arm Arm Collimator : 0.61709
HacR_HPM_LVDT:VALr : -4714
HacR_VPM_LVDT:VALr : 87
HacR_HPE1313A:0_Ch58 : -0.546875
HacR_HPE1313A:0_Ch55 : 21.9238
HacR_HPE1313A:0_Ch54 : -0.917969
HacR_alignROLL : -0.438519
HacR_alignPITCH : -0.00790367
HacR_alignHPT : 2.492
HacL_HPM_LVDT:VALr : -6528
HacL_VPM_LVDT:VALr : 881
HacL_HPE1313A:0_Ch58 : -0.169434
HacL_HPE1313A:0_Ch55 : 23.3887
HacL_HPE1313A:0_Ch54 : -0.282227
HacL_alignROLL : 0.0820771
HacL_alignPITCH : -0.0930777
HacL_alignHPT : 3.53439
Right Arm Angle Floor Angle : 40
Right Arm Angle Vernier : -34.5
Right Arm Scattering Angle : 39.9813
Left Arm Angle Floor Angle : 30
Left Arm Angle Vernier : 31.5
Left Arm Scattering Angle : 29.9786
Wien angle :
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 299
Laser power Hall A : 63
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88