    Log entry time 21:57:48 on October 1,2000

    Entry number 48960

    keyword=ep energy measuerment--prelim value

    EP energy measurement
    Raster off
    5.4 micro Amps
    ~ 1 hr
    run 3009
    E = 826.45 +- 0.36 stat
    coplanarity spectrum is fair, rates low, beam stable, should be a good number !!