User name adev
Log entry time 00:09:20 on October 2, 2000
Entry number 48973
keyword=Start_Run_1278_Tar=lead-cool,Type=Other,Pmom=0.756,Emom=0.821,Ene=826,Angle_e=14.993,Angle_h=53.768
Beginning-of-run EPICS data for Run Number 1278 at Mon Oct 2 00:09:08 EDT 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=10,ps2=10000,ps3=10000,ps4=50000,ps5=1000,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 617.295
Right Arm Q1 momentum : 0.820942
Right Arm Q1 gauss meter : -0.015481
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 353.202
Right Arm Q2 momentum : 0.820699
Right Arm Q2 gauss meter : 0.18592
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 282.187
Right Arm D1 momentum : 0.821002
Right Arm D1 NMR : 0.304664
Right Arm Q3 power supply current : 326.529
Right Arm Q3 momentum : 0.820614
Right Arm Q3 gauss meter : 0.14648
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 568.435
Left Arm Q1 momentum : 0.755564
Left Arm Q1 gauss meter : -0.04814
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 325.734
Left Arm Q2 momentum : 0.756466
Left Arm Q2 gauss meter : 0.17226
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 252.109
Left Arm D1 momentum : 0.755998
Left Arm D1 NMR : 0.279955
Left Arm Q3 power supply current : 300.976
Left Arm Q3 momentum : 0.755996
Left Arm Q3 gauss meter : -0.14989
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 0.517885
Current on Unser monitor : 0.982567
Current on Upstream bcm : 0.522064
Current on Downstream bcm : 0.513705
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 0.335717
Beam energy : 825.959
MBSY1c magnet current (amp) : 34.0388
Radiator 5V Linear Supply :
Radiator Encoder :
haBDSPOS : 991008
haL1_Fan_frequency_R : 67
haL2_Fan_frequency_R : 42.5
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 243.06
haSC200_6_Sensor_2_R : 222.02
haSC200_6_Sensor_3_R : -0.23
haSC200_6_Sensor_4_R : 35.57
haHe_Omega_DPG_Sensor_R : 5.696
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.78
haITC502_1_Sensor_3_R : 5.84999
haITC502_4_Sensor_1_R : 6
haITC502_4_Sensor_2_R : 4.9
haITC502_4_Sensor_3_R : 78.1
haITC502_5_Sensor_1_R : 5.83
haITC502_5_Sensor_2_R : 5.81
haITC502_5_Sensor_3_R : 181.8
haITC502_6_Sensor_1_R : 5.81
haITC502_6_Sensor_2_R : 5.8
haITC502_6_Sensor_3_R : 26.97
Right Arm Arm Collimator : 0.615039
Left Arm Arm Collimator : 0.617041
HacR_HPM_LVDT:VALr : -1304
HacR_VPM_LVDT:VALr : -801
HacR_HPE1313A:0_Ch58 : -0.561035
HacR_HPE1313A:0_Ch55 : 22.0215
HacR_HPE1313A:0_Ch54 : -0.85791
HacR_alignROLL : -0.377849
HacR_alignPITCH : 0.00549173
HacR_alignHPT : -1.30411
HacL_HPM_LVDT:VALr : -7468
HacL_VPM_LVDT:VALr : -648
HacL_HPE1313A:0_Ch58 : -0.320312
HacL_HPE1313A:0_Ch55 : 23.3887
HacL_HPE1313A:0_Ch54 : -0.363281
HacL_alignROLL : 0.00787054
HacL_alignPITCH : 0.0418252
HacL_alignHPT : 4.60651
Right Arm Angle Floor Angle : 15
Right Arm Angle Vernier : -37
Right Arm Scattering Angle : 14.9926
Left Arm Angle Floor Angle : 53.5
Left Arm Angle Vernier : 83
Left Arm Scattering Angle : 53.7682
Wien angle :
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 160
Laser power Hall A : 63
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88