User name adev
Log entry time 01:07:22 on October 2, 2000
Entry number 48986
keyword=Start_Run_1286_Tar=lead-cool,Type=Other,Pmom=0.756,Emom=0.821,Ene=826,Angle_e=14.993,Angle_h=53.768
Beginning-of-run EPICS data for Run Number 1286 at Mon Oct 2 01:07:09 EDT 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=4,ps2=10000,ps3=10000,ps4=50000,ps5=1000,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 617.26
Right Arm Q1 momentum : 0.820896
Right Arm Q1 gauss meter : -0.015486
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 353.347
Right Arm Q2 momentum : 0.821036
Right Arm Q2 gauss meter : 0.18598
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 282.187
Right Arm D1 momentum : 0.821002
Right Arm D1 NMR : 0.304664
Right Arm Q3 power supply current : 326.507
Right Arm Q3 momentum : 0.820557
Right Arm Q3 gauss meter : 0.14648
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 568.435
Left Arm Q1 momentum : 0.755564
Left Arm Q1 gauss meter : -0.04811
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 325.519
Left Arm Q2 momentum : 0.755966
Left Arm Q2 gauss meter : 0.17233
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 252.112
Left Arm D1 momentum : 0.755997
Left Arm D1 NMR : 0.279954
Left Arm Q3 power supply current : 301.107
Left Arm Q3 momentum : 0.756324
Left Arm Q3 gauss meter : -0.14991
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 19.4262
Current on Unser monitor : 21.0701
Current on Upstream bcm : 19.5747
Current on Downstream bcm : 19.1565
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 19.5986
Beam energy : 825.959
MBSY1c magnet current (amp) : 34.0388
Radiator 5V Linear Supply :
Radiator Encoder :
haBDSPOS : 991008
haL1_Fan_frequency_R : 65.5
haL2_Fan_frequency_R : 39
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 243.01
haSC200_6_Sensor_2_R : 221.92
haSC200_6_Sensor_3_R : -0.3
haSC200_6_Sensor_4_R : 35.55
haHe_Omega_DPG_Sensor_R : 5.698
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.78
haITC502_1_Sensor_3_R : 5.84999
haITC502_4_Sensor_1_R : 6
haITC502_4_Sensor_2_R : 4.9
haITC502_4_Sensor_3_R : 78.3
haITC502_5_Sensor_1_R : 5.83
haITC502_5_Sensor_2_R : 5.81
haITC502_5_Sensor_3_R : 182.3
haITC502_6_Sensor_1_R : 5.81
haITC502_6_Sensor_2_R : 5.79
haITC502_6_Sensor_3_R : 26.98
Right Arm Arm Collimator : 0.364209
Left Arm Arm Collimator : 0.617041
HacR_HPM_LVDT:VALr : -1308
HacR_VPM_LVDT:VALr : -778
HacR_HPE1313A:0_Ch58 : -0.562012
HacR_HPE1313A:0_Ch55 : 21.9238
HacR_HPE1313A:0_Ch54 : -0.856445
HacR_alignROLL : -0.376371
HacR_alignPITCH : 0.00407964
HacR_alignHPT : -1.30246
HacL_HPM_LVDT:VALr : -7468
HacL_VPM_LVDT:VALr : -641
HacL_HPE1313A:0_Ch58 : -0.319336
HacL_HPE1313A:0_Ch55 : 23.3398
HacL_HPE1313A:0_Ch54 : -0.362793
HacL_alignROLL : 0.00970607
HacL_alignPITCH : 0.040445
HacL_alignHPT : 4.60674
Right Arm Angle Floor Angle : 15
Right Arm Angle Vernier : -37
Right Arm Scattering Angle : 14.9926
Left Arm Angle Floor Angle : 53.5
Left Arm Angle Vernier : 83
Left Arm Scattering Angle : 53.7682
Wien angle :
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 180
Laser power Hall A : 63
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88