User name R. Michaels
Log entry time 01:27:08 on October 2,2000
Entry number 48993
keyword=current scan on lead (part I)
Put beam at +1.7 mm. This is nominal center.
Put sieve slit in to reduce rates.
Turn off all VDCs.
We will crank up the current and watch the rate, temperature.
Run #........Current..........Rate.........Temp (CH3).........Loop 2 return
1283............5.3...............3.4 kHz......182......................5.2
1285...........10.................6.7 kHz.......182......................5.2
1286............20................12 kHz........182......................5.0.....CODA fixed
1287............30................18................183.....................5.0
1288............40................25...............185......................5.1
1289............50.................32...............186
Now MCC takes away the beam to look at the location
on dump. Test will resume shortly