User name adev
Log entry time 03:03:17 on October 2, 2000
Entry number 49000
keyword=Start_Run_1292_Tar=lead-cool,Type=Other,Pmom=0.756,Emom=0.821,Ene=826,Angle_e=14.993,Angle_h=53.768
Beginning-of-run EPICS data for Run Number 1292 at Mon Oct 2 03:03:03 EDT 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=20,ps2=10000,ps3=10000,ps4=50000,ps5=1000,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 617.365
Right Arm Q1 momentum : 0.821035
Right Arm Q1 gauss meter : -0.015477
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 353.533
Right Arm Q2 momentum : 0.821467
Right Arm Q2 gauss meter : 0.18599
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 282.179
Right Arm D1 momentum : 0.820999
Right Arm D1 NMR : 0.304663
Right Arm Q3 power supply current : 326.851
Right Arm Q3 momentum : 0.821421
Right Arm Q3 gauss meter : 0.14651
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 568.435
Left Arm Q1 momentum : 0.755564
Left Arm Q1 gauss meter : -0.04812
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 325.456
Left Arm Q2 momentum : 0.755821
Left Arm Q2 gauss meter : 0.17226
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 252.112
Left Arm D1 momentum : 0.755999
Left Arm D1 NMR : 0.279955
Left Arm Q3 power supply current : 301.068
Left Arm Q3 momentum : 0.756227
Left Arm Q3 gauss meter : -0.14991
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 11.8139
Current on Unser monitor : 13.5058
Current on Upstream bcm : 11.9626
Current on Downstream bcm : 11.6652
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 11.9254
Beam energy : 825.959
MBSY1c magnet current (amp) : 34.0388
Radiator 5V Linear Supply :
Radiator Encoder :
haBDSPOS : 991010
haL1_Fan_frequency_R : 64.5
haL2_Fan_frequency_R : 38.5
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.96
haSC200_6_Sensor_2_R : 222.07
haSC200_6_Sensor_3_R : -0.27
haSC200_6_Sensor_4_R : 35.54
haHe_Omega_DPG_Sensor_R : 5.77
haITC502_1_Sensor_1_R : 5.81
haITC502_1_Sensor_2_R : 5.78
haITC502_1_Sensor_3_R : 5.84999
haITC502_4_Sensor_1_R : 6
haITC502_4_Sensor_2_R : 4.9
haITC502_4_Sensor_3_R : 75.8
haITC502_5_Sensor_1_R : 5.83
haITC502_5_Sensor_2_R : 5.81
haITC502_5_Sensor_3_R : 184.8
haITC502_6_Sensor_1_R : 5.82
haITC502_6_Sensor_2_R : 5.83
haITC502_6_Sensor_3_R : 27.04
Right Arm Arm Collimator : 0.364258
Left Arm Arm Collimator : 0.616992
HacR_HPM_LVDT:VALr : -1315
HacR_VPM_LVDT:VALr : -762
HacR_HPE1313A:0_Ch58 : -0.561035
HacR_HPE1313A:0_Ch55 : 21.9727
HacR_HPE1313A:0_Ch54 : -0.855957
HacR_alignROLL : -0.376428
HacR_alignPITCH : 0.00466025
HacR_alignHPT : -1.29372
HacL_HPM_LVDT:VALr : -7471
HacL_VPM_LVDT:VALr : -633
HacL_HPE1313A:0_Ch58 : -0.318848
HacL_HPE1313A:0_Ch55 : 23.3887
HacL_HPE1313A:0_Ch54 : -0.362305
HacL_alignROLL : 0.0105895
HacL_alignPITCH : 0.040445
HacL_alignHPT : 4.60855
Right Arm Angle Floor Angle : 15
Right Arm Angle Vernier : -37
Right Arm Scattering Angle : 14.9925
Left Arm Angle Floor Angle : 53.5
Left Arm Angle Vernier : 83
Left Arm Scattering Angle : 53.7682
Wien angle :
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 120
Laser power Hall A : 63
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88